EN
13
3.8.1 Menu: SETUP
General settings:
Note:
The change in the programming menu is avai-
lable from both the main screen
“pause“
as well as
from the detail overview display
“PAUSE“
.
p
a
u
s
e
PERM
3.2
bar
PUMP
_
_
_
bar
25–
06
–
13
09
:
02
PAUSE
16
_
_
_
a
Confirm with the
[
✓
] button
to shift into the
programming menu.
EXIT
SERVICE
FLUSH TIME
AUTO RINSE
SETUP
Fig. 10:
Main selection menu: “SETUP“
The “SETUP“ selection menu appears:
a
The menu item
“DATE“
is active.
DATE /
TIME
Date
;
time
CONDUCTIVITY / TDS
Conductivity value / TDS (ppm)
OPERATION MODE
Pressure tank operation: Yes/No
LANGUAGE
Setting of the menu language
BACK
Quit menu and return to selection menu
Fig. 11:
Display of the activated “SETUP“ menu.
Perform the general settings of the
“SETUP“
selection menu in
accordance to:
Fig. 12, Fig. 13, Fig. 14
.
The description of the parameter setting
“FLUSH TIME“
is given at
Fig. 14
.
3.7 Device settings/visualisation
Note:
All of the programable settings described in
Part
3.7
can only be accessed and activated in the
“PAUSE”
mode.
Visualisation of the menu screens/displays:
Note:
The illustrations in the software schemes serve
for a better overview and are subsequently described.
In each menu screen the
blue light bar
highlights the
current active menu item
or
value set
.
AUTO RINSE
ACTIVE
SERVICE
INACTIVE
FLUSH TIME
INACTIVE
SETUP
INACTIVE
EXIT
3.8 Main menu
The menu consists of 4 selectable menu items in which the
subsequent settings may be effected:
AUTO RINSE:
• Mode for automatic flushing.
SERVICE:
• Settings of setpoint- and limit values for service purpose.
FLUSH TIME:
• Setting of flush time after the completion of
permeate production
SETUP:
• General device settings (date, time, language, limit values,
operating mode).
The recommended target values of all settings
are documented in the form “Form for set values
of BWT bestaqua 22,24,26 HQ“ (see Part 7.1).
Document the parameters
after you have set all of
the data at the device.
Please use the template at the end of the operating