MENU SETTINGS 

 
 
Press the “MENU” button (button 2) to bring up the programming selections. Pressing the “MENU” button 
again will cycle through the selections as follows: 
 
Frequency 

 Power Level 

 Unit Number 

  then back to frequency if pressed again. 

 

FREQUENCY 

The frequency number from 1 

– 8 should be displayed on the bottom line. Pressing the Power/Select 

button will bring up a blinking cursor and allow the frequency to be changed. Press the Power/Select 
button until the desired frequency is selected then Press Menu to save. The display should show 
Saving….. then “Done” when complete. 
 

POWER LEVEL 

The power level, either “Low”, “Mid”, or “High”, should be displayed on the bottom line. Pressing the 
Power/Select button will bring up the blinking cursor and allow the power level to be changed to any of 
the aforementioned settings. Press the Power/Select button to change the setting then the Menu button to 
save the setting.  
 

UNIT NUMBER 

When first received the transmitter Unit number will be “None”. This must be set to either Unit #1 or Unit 
#2 before the transmitter can be used. The Unit number will be saved in EEPROM memory so that it will 
always save this setting. It will be cleared back to “None” if “Clear” is selected. 
 
Press the Power/Select button to bring up the flashing cursor. Pressing Power/Select again will cycle 
through Unit # 1

…Unit #2...Clear. Press “Menu” when the correct unit number is selected to save the 

setting. You’ll see “Saving…” then “Done” when complete. 
 
 

SYSTEM ON/OFF 

 

SYSTEM ON 

Depress and hold the Power/Select button. The display 

will show 3….2….1… then “Power On” when the 

unit has turned on. Release the Power/Select button and the unit will begin to transmit a beacon signal to 
the receiver approximately every 0.5 seconds 
 
NOTE:  If Unit Number hasn’t been set the display will show “Select Unit # First”. See the “UNIT 
NUMBER”  section in “MENU SETTINGS” 
 

SYSTEM OFF 

Depress and hold the Power/Select button. The display will count down 3…2…1 then “Power Off” when 
the unit has turned off. At this point the beacon will stop and a log out code will be transmitted to the 
receiver. This will turn off the corresponding ‘login’ relay on the receiver and allow the transmitter to log 
back in later 
 
NOTE: If the Power/Select button is released at any point during the power on/off countdown the unit will 
stay in its current state and the countdown timer will reset. 
 
 
 
 
 
 