background image

461-8000-AC

 

 

SPECIFICATIONS 

 

Power Supply 

100-250 VAC, 5 W, 50/60 Hz 

Relay Contacts  

SPDT 5 amp @ 120VAC or 30VDC per channel 

Fuse Protected 

1 amp 

Receiver Frequency 

902-928 MHz Spread Spectrum 

Receiver Range 

Up to 1 Mile (Up to 10 miles with external antenna - 
see accessories) 

Note:  Range figures are estimates, based on free-air terrain with limited sources of interference. 
Actual range will vary based on transmitting power, orientation of transmitter and receiver, height 
of transmitting antenna, height of receiving antenna, weather conditions, interference sources in 
the area, and terrain between receiver and transmitter, including, but not limited to, indoor and 
outdoor structures such as walls, metal objects, trees, buildings, hills, and mountains. 

Receiver Channels 

Eight independent network frequencies 

Operating 
Temperature 

-40

o

 F to +185

o

 F 

Enclosure 

Polycarbonate, IP66 (NEMA 4) 

Weight 

Approx 2.11 lbs. 

 

 

ACCESSORIES 

 

STANDARD ANTENNA (INCLUDED)

 

900MHz 

TNC Portable “Rubber Duck” Antenna 

49-1103 

MOBILE/BASE ANTENNAS (OPTIONAL) 

Used to help achieve max range in non-line-of-sight and line-of-sight applications. 

Contact BWI Eagle for recommendations.

 

900MHz Thru-Hole/Bracket Mount Mobile Antenna 

49-2101 

900MHz Magnet Mount Mobile Antenna 

49-2102 

900MHz Omni Directional Base Antenna 

49-3101 

900MHz Yagi Directional Base Antenna 

49-3102 

HIGH QUALITY COAX CABLE 

Used to connect external antennas to control unit.

 

Flex Coax Cable w/Connectors 
(Available in 5’, 15’, 25’, 30’, 40’, 60’, 80’, and 100’ lengths) 

49-4000-XX 
(XX = length in feet) 

BULKHEAD EXTENSION 

Used to provide an external antenna connection when mounting control unit 

inside another enclosure.

 

TNC Male to TNC Bulkhead Cable Assembly 
(Available in 2’, 4’, and 7’ lengths) 

49-5004-X-ISO 
(X = length in feet) 

 

Содержание Air-Eagle XLT PLUS 461-8000-AC

Страница 1: ...AIR EAGLE XLT PLUS 461 8000 AC 900 MHz RF Receiver Document Date 7 6 2021 Product Rev 1...

Страница 2: ...f merchantability and fitness for a particular purpose Some jurisdictions do not allow the exclusion of implied warranties so this limitation may not apply to you To obtain warranty service contact BW...

Страница 3: ...ipped with 4 independent relays that can switch 5 amps 120VAC or 30VDC The relays are user programmable for momentary or toggle latching operation and can be directly interfaced with the customer s eq...

Страница 4: ...ach rubber duck antenna or coax from external antenna to connector on side of enclosure 5 Connect supplied power input cable to your external power source TERMINAL STRIP WIRING Terminal 1 100 250 VAC...

Страница 5: ...461 8000 AC 4...

Страница 6: ...f for 15 20 seconds then reapply power LED2 Illuminates green while relay 1 is energized LED3 Illuminates green while relay 2 is energized LED4 Illuminates green while relay 3 is energized LED5 Illumi...

Страница 7: ...omentary default Relay 2 toggle latch SW3 Relay 3 momentary default Relay 3 toggle latch SW4 Relay 4 momentary default Relay 4 toggle latch Maintained Momentary Relay mimics button or input when depre...

Страница 8: ...ht independent network frequencies Operating Temperature 40o F to 185o F Enclosure Polycarbonate IP66 NEMA 4 Weight Approx 2 11 lbs ACCESSORIES STANDARD ANTENNA INCLUDED 900MHz TNC Portable Rubber Duc...