AIR-EAGLE
®
XLT
900 MHz RF Receiver
MODEL 44UL-2000-DC
RELAY MODES OF OPERATION
Auto Reset (Maintained Momentary)
When signal is received from an authorized transmitter, the relay will
energize. The relay will maintain the energized state as long as the
transmitter is sending the signal. The relay de-energizes when the
transmitted signal stops.
Toggle Reset (Toggle Latch)
When a signal is received from an authorized transmitter, the relay will
energize and latch. The relay stays energized until the same signal is
received again, at which time it unlatches and de-energizes.
Latching Reset (True Latch)
When a signal is received from an authorized transmitter, the relay will
energize and latch. The relay stays energized until a different signal is
received from the transmitter, at which time it unlatches and de-energizes.
i.e.
– Transmission from Input 1 of authorized transmitter energizes and
latches relay 1. Transmission from Input 2 of an authorized transmitter de-
energizes relay 1.
RELAY & FREQUENCY SET-UP
The unit is shipped from the factory with SEL1 switches in the open
positions. All four relays will operate as maintained momentary and unit is
receiving commands on frequency one. If you wish to change these
default settings, follow the instructions on the table below.
1) Remove power from unit
2) Remove top cover.
3) Select desired relay operation and/or network frequency using table
below.
4) Reattach cover and apply power.
5) Programming is now complete.
RELAY CONFIGURATION
SEL1
SWITCH
NUMBER
OPEN
CLOSED
SW1
Relay #1 momentary
(default)
Relay #1 toggle/latch
SW2
Relay #2 momentary
(default)
Relay #2 toggle/latch
SW3
Relay #3 momentary
(default)
Relay #3 toggle/latch
SW4
Relay #4 momentary
(default)
Relay #4 toggle/latch
FREQUENCY SET-UP
SEL1
(SW5-7)
Network
Frequency
SW5
SW6
SW7
1
(default)
OPEN
OPEN
OPEN
2
CLOSED
OPEN
OPEN
3
OPEN
CLOSED
OPEN
4
CLOSED
CLOSED
OPEN
5
OPEN
OPEN
CLOSED
6
CLOSED
OPEN
CLOSED
7
OPEN
CLOSED
CLOSED
UL SPECIFICATIONS & CLASSIFICATIONS
SPECIFICATIONS
DC Input
10
– 24 VDC @ 10 Watts
Relay Contacts
SPDT 5 amp @ 120VAC or 30VDC
Fuse Protected
1 amp
Receiver Frequency
900 MHz Spread Spectrum
Receiver Range
Approximately 2500 feet (Up to 4 miles
with external high gain antenna)
Receiver Channels
Seven independent network frequencies
Operating Temperature
-10
o
C to +55
o
C
Altitude
Under 2000 meters
Enclosure
Polycarbonate, IP66 Approved
Weight
Approx 2 lbs.
CLASSIFICATIONS
Automatic Control and Electrically Operated Control
Incorporated Control and an Independently Mounted Control
Type 1.C Action; Micro-Interruption
PTI of Materials Used for Insulation: Material Group IIIb
Electrical Shock Risk: Class II Control
Period of Electrical Stress Across Insulating Parts Supporting Live
Parts: Long Period
Pollution Degree 2
Number of Cycles of Activation: 30,000 (Relay)
DIMENSIONS
Page 2