PRODUCT INFORMATION 

BULLETIN 

 

 

 

105 Bonnie Drive 
Butler, PA 16002 
724-283-4681 
724-283-5939 (fax) 
www.bwieagle.com

 

 
 
 
 

 

 

 

AIR-EAGLE

®

 

XLT 

900 MHz RF Receiver 

MODEL 44UL-2000-DC 

 
 

DESCRIPTION

 

 
The A

IR

-E

AGLE 

XLT

 

is a UL/CSA approved RF system designed for 

medium to long range wireless remote control of electrical apparatus in a 
variety of industrial applications.  Systems can consist of any number of 
receivers and handheld or contact input transmitters working together. 
This receiver is equipped with 4 independent relays that can switch 5 
amps @ 120VAC or 30VDC. The relays are user programmable for 
momentary or toggle/latching operation and can be directly interfaced with 
the customer's equipment or P.L.C.  Seven user selectable frequencies 
allow multiple systems to be used in the same area.  Capable of receiving 
remote signals transmitted from up to 2500 feet away (with the handheld 
transmitter) or up to 2 miles away (with the contact input transmitter), the 
Air-Eagle XLT utilizes spread-spectrum technology and provides the 
utmost security and reliability even in the noisiest RF environments. 

 

Please read through this document in its entirety before proceeding 
with installation. 

 

INSTALLATION 

 

DISCONNECT DC Power from all equipment before installation. 

 

1. 

Mount the control unit in a suitable location that allows the user to 
easily remove the lid of the enclosure for wiring access. When 
possible select a location that is not directly beside high energy 
transformers or large inductive relay housings. It is recommended to 
allow for a minimum of 

2.0” clearance on all sides of the unit’s 

housing & mounting plate. The power and control wiring exiting thru 
the provided cord grips should have ample room to bend without 
excessive stress. It is also important that any coax cable connected 
to the TNC connector 

have room to bend without “kinking”. 

2. 

Install relay wiring to terminal strip (TER1). 

3. 

Attach supplied rubber duck antenna to TNC connector on the right 
side of the unit.  

4. 

Connect DC power to the proper terminals in your control circuit. 

 
Note 1: (6) #10 thru holes & (4) 1/4-20 thru holes are provided on the 
mounted plate to secure the unit) 
 
Note 2: The recommended power/control wire sizes to the terminal strip 
ranges from 24 AWG (0.205mm2) (min) to 18 AWG (0.823mm2) (max). 

 

TERMINAL STRIP WIRING 

N/O Relay #1 

N/O Relay #3 

13  (-) 10 

– 24 VDC  

C Relay #1 

C Relay #3 

14  (+) 10 

– 24 VDC  

N/C Relay #1 

N/C Relay #3 

 

N/O Relay #2 

10  N/O Relay #4 

C Relay #2 

11  C Relay #4 

N/C Relay #2 

12  N/C Relay #4 

 

 

 

CONTROLS AND INDICATORS 

 

 

 

LED1 

Illuminated when power is applied to receiver 

LED2 

Illuminated when relay #1 is energized 

LED3 

Illuminated when relay #2 is energized 

LED4 

Illuminated when relay #3 is energized 

LED5 

Illuminated when relay #4 is energized 

RF1 

RF module that receives data from the remote 
transmitter 

REL1 thru REL4 

Four SPDT output control relays  

SEL1 

Seven dip switches for selecting relay options 
and operating frequency 

 

Page 1 