11
NOTE: Some controllers may include a WL terminal
between COM1 and WH. The WL terminal is not
used.
If no probe is used, place a jumper wire between
COM1 and WH.
ELECTRICAL CONNECTIONS
Wiring Diagram for Controller
Please note: Board configuration and layout may differ slightly to the example shown, always read
and follow labeling for correct wiring.
*** Low water and tank /
pressure switch wires have no polarity for
connection.
*** Pump cable wires must
Be connected by number.
1, 2, 3
SYS
Pump MPPT ERR_1 Low
Pwr
Tank F Well L
Timer Control
Speed Control
P+
P-
B+ B-
1
2
3 COM2 TH COM1
WH
SOLAR
BAT
Tank Float
Or pressure
switch with
N.O. contacts
Low Water Sensor
Pump
Controller ON/OFF Switch
may be in a different position
and labelling to the one
shown
Electrical specifications, including maximum
VOC, is available on the controller label.