background image

BVV Models BVV2CY & BVV4CY 

Refrigerant Recovery Pump 

Operation Manual

ISA 12.12.01:2016 Ed.7 

Nonincendive Electrical 

Equipment For Use In Class I 

and Ii, Division 2 and Class Iii, 

Divisions 1 And 2 Hazardous 

(Classified) Locations

Model BVV2CY

Model BVV4CY

Only qualified personnel trained in the handling of flammable and non-flammable 

refrigerants should operat

e

 this piece of equipment. Working with refrigerants under 

pressure presents numerous safety risks and hazards.

Содержание BVV2CY

Страница 1: ...In Class I and Ii Division 2 and Class Iii Divisions 1 And 2 Hazardous Classified Locations Model BVV2CY Model BVV4CY Only qualified personnel trained in the handling of flammable and non flammable re...

Страница 2: ...hazards Read and understand this operator s manual and all safety materials before using Failure to properly use this unit correctly can result in personal injury and or equipment damage TABLE OF CONT...

Страница 3: ...may contain liquid refrigerant under pressure Contact with refrigerant may cause frostbite or other related injuries Wear proper personal protective equipment such as safety goggles and gloves When d...

Страница 4: ...required DANGER EXPLOSION RISK Do not mix flammable refrigerants with air All precautions must be taken to eliminate the mixing of air with flammable refrigerants including monitoring the recover cyli...

Страница 5: ...x WC TW Turn on the scale and tare to Zero Place storage tank on scale Read the weight Compare that to the MTW calculated above If the scale weight is below MTW you still have storage capacity you hav...

Страница 6: ...0 amps 2 4 350 PSIG 32F to 105F 18 0 x 10 0 x 12 0 25 0 lbs 35 0 lbs Motor Type Maximum Current Number of Cylinders High Pressure Cutout Operating Temperature Range Dimensions Weight Plug and Play Un...

Страница 7: ...omp Module 1 2 NPT Discharge Port 1 2 NPT Suction Port LED IEC Socket PCB Module High Pressure Switch BVV4CY BVV2CY START STOP button 2 CYL Comp Module LED IEC Socket High Pressure Switch 3 8 JIC Disc...

Страница 8: ...scharge valve seats Warranty may be void if oil and resins are present 3 Plug unit into either a 115V or 230V power source The Indicator LED will flash GREEN 4 Once it is determine the unit is to begi...

Страница 9: ...r at power source Check core depressor on connecting hoses Valve core on system being recovered not fully depressed RED LED CODE FAULT INDICATED POSSIBLE SOLUTION 3 Flashes Excessive pressure in recov...

Страница 10: ...10 ELECTRICAL PLUMBING SCHEMATICS PARTS LIST BVV 1251 Frontenac Road Ste 150 Naperville IL 60563...