DESCRIPTION
Cooling Distance:
ECO-033
UP TO 50’
of cooling line
ECO-050
UP TO 75’
of cooling line
MM-033
UP TO 75’
of cooling line
CWA-3 / CWW-3
UP TO 125’
of cooling line
CWA-2 / CWW-2
UP TO 250’
of cooling line
CWA-34 / CWW-34
UP TO 350’
of cooling line
Current draw per unit:
ECO-033
ECO-050
MM-033
CWA-3/
CWW-3
CWA-2/
CWW-2
CWA-34/
CWW-34
Voltage
115 115 115 115 115
208/230
Start-Up
9.5A 9.5A 9.5A 9.8A 10.6A 7.5A
Running
7.2A 7.2A 7.2A 7.1A 7.9A 5.3A
Refrigerant R134a
R134a
R134a
R-22
R-22
R-22
Charge
10 oz.
16 oz.
10 oz.
16 oz.
21 oz.
36 oz.
Tank Capacity
3 gal.
3 gal.
4 gal.
12 gal.
12 gal.
12 gal.
Foam
insulation
1” 1” 1” 1” 1” 1”
Weight
65 lbs.
70 lbs.
97 lbs.
106 lbs.
113 lbs.
134 lbs
Pressure
18 (low)
150 (high)
18 (low)
150 (high)
18 (low)
150 (high)
43 (low)
220 (high)
43 (low)
220 (high)
43 (low)
220 (high)
Pump
(Gravity Fed)
50 GPH
(Vertical)
50 GPH
(Vertical)
50 GPH
(Pressure)
80 GPH
(Gear)
80 GPH
(Gear)
80 GPH
(Gear)
Dimensions
(inches)*
H: 14.0
W: 24.5
D: 24.5
H: 14.0
W: 24.5
D: 24.5
H: 13.0
W: 23.5
D: 22
H: 28.5
W: 16.75
D: 26.5
H: 28.5
W: 16.75
D: 26.5
H: 29.5
W: 18
D: 26.5
*Dimensions include pump and motor.