User manual
www.bvfheating.com
CLOCK
& 5+1+1 PRG SETTING
PRG function allows you to set different temperatures throughout the day. For example, you may want the home warm in the morning, cooler when you leave it for
the day, and then warmer in the evening when you return. The thermostat offers 5+1+1 programming option, four different temperature levels for each day. Default
comfort levels are pre-programmed; still you can change them easily with the following method:
KEY-LOCK
FUNCTION
In order to avoid unauthorised access (hotels, public areas, child room) you can activate the key lock function from parameter settings page 12. To unlock your device
long press the and buttons for ~5 seconds.
DEFAULT
VALUES
PARAMETER
SETTINGS
WIRING
DIAGRAM
During the power off mode, to access or modify parameter settings, please press and hold the
and
buttons simultaneously for ~8 seconds until the MENU
appears showing 01 which is menu 1. Each press of the button goes to the next MENU.
Press and hold button for 5 seconds,
1.
press and to adjust the clock (min-hour-weekday), each press of will go into the next setting,
2.
after the clock adjustment, press to change the 5+1+1 mode. By pressing and you can set the desired time and temperature of each period.
(Weekday- period- time- temp.) Each press of the button goes into the next item setting.
Period
Wake up 1
Leave Home 2
Return Home 3
Sleep 4
Time
Temp.
Time
Temp.
Time
Temp.
Time
Temp.
1-5 (Mon.-Fri.)
7:00
22°C
8:30
19°C
17:00
22°C
22:00
19°C
6 (Sat.)
8:00
22°C
8:30
22°C
17:00
22°C
22:00
19°C
7 (Sun.)
8:00
22°C
8:30
22°C
17:00
22°C
22:00
19°C
7
EXTERNAL SENSOR
3600W/16A
230V/AC
6
5
4
3
2
1
Menü
Description
Range
Default
01
Temp. Offset
-8°C ~ 8°C
0
02
Set Point Max.
5°C ~ 80°C
35°C
03
Set Point Min.
5°C ~ 80°C
5°C
04
Sensor Select
ROOM
SURFACE
Room + Surface
05
Frost Protection Temp.
5°C ~15°C
5°C
06
Surface Temp. Display
Read Only
07
High Temp. Protection
10°C ~ 80°C
32°C
11
Reset
rE(Yes)
12
Key lock
0 - off, 1 - on
0
13
Master ID address
Read Only
14
OWD function ON/OFF Select
0 - off, 1 - on
0
15
OWD Detect Time Select
2 ~ 30 mins
15 mins
16
OWD Drop Temp. Select (within detect time)
2 / 3 / 4°C
2°C
17
OWD Delay time select (Return to previous working status)
10 ~ 60 mins
30 mins
18
The temp. diff to exit high protection mode
1°C ~ 3°C
1°C
19
External sensor temp. offset
-8°C ~ 8°C
0
20
Energy optimisation
1: electric radiator 3: ceiling heating
2: heating panel 4: floor heating
2
21
Brightness (Standby Mode)
0 - 100%
5%
22
Software version
Read Only
v1.5 EN (07.02.2019)