3. INSTALLATION

Before installing the thermostat check if the necessary preparations have been made. You can 

find  the  relevant  details  in  the  instructions  manual  of  the  heating  system  to  be  used.  The  BVF 

Heato9 thermostat can be mounted in a recessed mounting box or on a surface mount frame. The 

dimensions of the recessed mounting box can be seen in the figure below:

The mounting box should always be of the screw type and be prepared for use with horizontally 

positioned mounting bolts. The thermostat should be installed in the following manner:
1. 

Make the relevant electrical circuit dead. Leave the performance of the electrical job to an 

expert.

2. 

Remove the front panel of the thermostat: when looking at the thermostat from the front, 

there is a rectangular-shaped recess at the bottom of the device on its two sides; insert and 

carefully press a thin screwdriver or phase indicator into this recess and you can now lift off 

the front panel. Take care not to break the plastic fixing lugs. In cold weather (below +5°C) 

plastic becomes brittle and the risk of breaking increases. If possible, install the the heating 

system at a temperature above +5°C.

3. 

The front and rear panels of the thermostat are connected by a pin-type connector. Upon 

removing the front panel this connector slides out of the rear panel. Put the removed front 

panel aside in a safe place, protecting it from damage.

4.  Carry out the electrical connection of the rear panel. (Item 4)

5. 

Mount the rear panel using the screws provided with the recessed mounting box or in the box 

of the thermostat. Take care to mount the rear panel in a way that the display on the mounted 

front panel can be properly read („upside up”). Make sure that the connected wires would not 

come out of the thermostat when mounting the rear panel.

6. 

Replace  the  front  panel;  make  sure  that  the  pins  of  the  pin-type  connector  remain  intact, 

undeformed and unbent. First the upper fixing points on the front panel should be fitted. 

Adjust the pin-type connector to the connection point on the rear panel.

7. 

Snap the front panel onto the rear panel: first fit the upper part of the display to the upper two 

lugs, then snap the lower two fixing lugs into place.

8. 

After turning the thermostat circuit on the circuit is live again and the device can be switched 

on.

External fixing screws must be placed in horizontal position!

55 mm

d 65 mm

Содержание Heato9

Страница 1: ...bvfheating com BVF Heato9 Programmable room thermostat DETAILED USER MANUAL...

Страница 2: ...3 2 Technical data dimensions switching current connection 3 3 Installation 4 4 Electrical connection 6 5 Display 7 6 Fix modes of operation 8 7 Programming 9 8 Factory settings menu points 10 9 Faul...

Страница 3: ...ntrolled equipment and make the guarantee null and void 2 TECHNICAL DATA dimensions switching current connection Supply voltage 230V AC 50 60 Hz Relay loadability 3600W 16A recommended max 3200W 14A S...

Страница 4: ...possible install the the heating system at a temperature above 5 C 3 The front and rear panels of the thermostat are connected by a pin type connector Upon removing the front panel this connector sli...

Страница 5: ...5 MOUNTING Electrical box recessed into the wall 65x 55mm horizontal screw locations...

Страница 6: ...the neutral blue wire of the electrical resistance based heating element here 4 Phase output Connect the phase brown conductor of the electrical resistance based heating element here Attention The hea...

Страница 7: ...sponding to the application and the related temperature can be set Setting of the programming is detailed in menu point 7 BVF logo In the upper right corner of the display the logo indicates the stand...

Страница 8: ...rmostat and to be achieved will not change until the or button is touched The steady temperature values make quick setting possible to provide constant temperatures with time inde pendent unchanged va...

Страница 9: ...isplay and the pp hh mm indication starts flashing in the right bottom corner Just like above set the next starting time of the daily program cycle The start of the 2nd program cycle will logically in...

Страница 10: ...ttention Saving of the settings will take place automatically even if no further steps follow and in about 15 seconds the thermostat will turn off In the factory menu after entering it again or settin...

Страница 11: ...a value higher than that even in the case when the room has not reached the desired temperature value A setting recom mended for floor or ceiling heating operated as an independent mode of heating 05...

Страница 12: ...he time specified here If the numerical value of the menu is 30 it means that heating will be switched on again 30 minutes after the temperature drop has stopped An example of how the open window func...

Страница 13: ...h it on again YES The thermostat has switched on the ribbon cable has pressed the front panel when replacing the front panel take care to insert the ribbon cable in the small gap on the rear side NO s...

Страница 14: ...limit values as described in the instructions manual If necessary the setting limit value can be increased If the surface temperature shows an unrealistic value further examination is required If ther...

Отзывы: