BVA PEM0501T Скачать руководство пользователя страница 4

• Read, understand, and follow all instructions provided with 

and on this device before use.

•  All WARNING statements must be carefully observed to 

help prevent personal injury.

• No alteration shall be made to this device.

•  Always wear protective gear when operating 

hydraulic equipment. Tie up long hair, wear 

eye and ear protection, and non slip foot 

wear.

•  Keep hydraulic equipment away from flames 

and heat. Hydraulic fluid can ignite and burn. 

Do not operate if leaks are detected.

•  Crush Hazard. Keep hands and feet away 

from loading area. Avoid pinch points or 

crush points that can be created by the load, 

cylinder, or  system components.

• To avoid crushing and related injuries:

  NEVER work on, under or around a lifted 

load before it is supported by appropriate 

mechanical means. Never rely on hydraulic 

pressure alone to support load.

HYDRAULIC PUMPS

• 

The  user  must  be  a  qualified  operator  familiar  with  the 

correct operation, maintenance, and use of pumps. Lack 

of knowledge in any of these areas can lead to personal 

injury.

• Do not exceed rated capacity of the pump or any equipment 

in the system. 

• Never attempt to lift a load weighing more than the capacity 

of the output device (cylinder, spreader etc.)

• Do not subject pump and its components to shock loads.

• Burst hazard exists if hose or connection pressure exceeds 

rated pressure.

• Inspect pump, cylinder, hoses and connections before each 

use to prevent unsafe conditions from developing. Do not 

use if they are damaged, altered or in poor condition. Do 

not operate the system with bent or damaged coupler or 

damaged threads.

• Never hold or stand directly in line with any hydraulic 

connections while pressurizing.

• ALWAYS use gauge or other load measuring instrument to 

verify load. 

• Never attempt to disconnect hydraulic connections 

under pressure. Release all line pressure before 

disconnecting hoses.

• Use of incorrect power source will damage the motor.

• Do not use an ungrounded (two-prong) extension cord.

• Do not install, remove or rewire the motor with power 

applied.  Have  qualified  technician  to  install,  adjust  and 

service the motor.

!

   

WARNING

• Do not operate this device in an extreme temperature, 

explosive atmosphere or in the presence of conductive 

liquids.

• Always inspect hoses and connections for damage prior 

to use. 

• Ensure the device is placed on a hard, level surface.

• Ensure that application is stable to work on and around. 

• 

Use  only  approved  accessories  and  approved  hydraulic 

fluid.

•  Never attach ANY component not authorized by 

manufacturer.

• Do not connect to application  which can return more oil to 

the reservoir than the pump reservoir can hold. 

• Do not connect pump to hydraulic system powered by 

another pump.

•  This device is not suitable for use as support device! As 

the system load is lifted, use blocking and cribbing to 

guard against a falling load.

• All personnel must be clear before lowering load or 

depressurizing the system.

•  Never try to disassemble a hydraulic pump, refer repairs 

to qualified, authorized personnel.

HYDRAULIC HOSES & FLUID TRANSMISSION LINES

•  Avoid short runs of straight line tubing. Straight line runs 

do not provide for expansion and contraction due to 

pressure and/or temperature changes.

• Reduce stress in tube lines. Long tubing runs should 

be supported by brackets or clips.  Before operating 

the pump, tighten all hose connections with proper 

tools. Do not overtighten. Connections should only be 

tightened securely and leak-free. Overtightening can 

cause premature thread failure or high pressure fittings 

to burst.

• Should a hydraulic hose ever rupture, burst or need to 

be disconnected, immediately shut off the pump and 

release all pressure. Never attempt to grasp a leaking 

pressurized hose with your hands. The force of escaping 

hydraulic fluid can inflict injury.

• Do not subject the hose to potential hazard such as fire, 

sharp objects, extreme heat or cold, or heavy impact.

•  Do not allow the hose to kink, twist, curl, crush, cut or bend 

so tightly that the fluid flow within the hose is blocked or 

reduced. Periodically inspect the hose for wear.

•  Do not pull, position or move setup by the hose.

•  Hose material and coupler seals must be compatible with 

hydraulic fluid used. Hoses also must not come in contact 

with corrosive materials such as battery acid, creosote-

impregnated objects and wet paint. Never paint a coupler 

or hose.

• 

FAILURE TO HEED THESE WARNINGS MAY RESULT 

IN  PERSONAL  INJURY  AS  WELL  AS  PROPERTY 

DAMAGE.

4

Содержание PEM0501T

Страница 1: ...230V50 PEWM3005T 230V50 Model PEM1002T 230V50 PEM1503T 230V50 PEM3005T 230V50 Model PEWM0501T 230V50 Maximum Operating Pressure 10 000 PSI for double acting applications only This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death SFA Companies 10939 N Pomona Ave Kansas City MO 6...

Страница 2: ...hydraulic fluid to compatible double acting applications ONLY Such applications include rams presses spreaders compactors and crimping machines anywhere that 10 000 PSI of double acting fluid pressure is needed Special skill knowledge and training may be required for a specific task and the product may not be suitable for all the jobs described above Unsuitable applications would include applicati...

Страница 3: ...pted repairs not performed by BVA Hydraulics or one of its authorized personnel improper fluid use or use of the product in any manner for which the product was not intended or the use of which is not in accordance with the instructions or warnings provided with the product In the unlikely event that a BVA Hydraulics product fails due to material defect in workmanship you may contact SFA for dis p...

Страница 4: ... this device in an extreme temperature explosive atmosphere or in the presence of conductive liquids Always inspect hoses and connections for damage prior to use Ensure the device is placed on a hard level surface Ensure that application is stable to work on and around Use only approved accessories and approved hydraulic fluid Never attach ANY component not authorized by manufacturer Do not connec...

Страница 5: ...le the ON OFF switch located on the control box to ON position OR for momentary use Leave control box switch in the OFF position and toggle remote ON OFF pendant switch 5 It is recommended to use to ON OFF switch at the control box to let the pump idle for a few minutes before putting into operation WARNING This pump is for use with a double acting cylinder ONLY Connect two hoses from the pump to ...

Страница 6: ...Use only good quality hydraulic oil We recommend BVA hydraulic oil F01 F05 Mobil DTE 15M or equivalent To order the oil refer to service parts section Use only the manufacturers recommended hydraulic oil Use of other hydraulic oil may result in pump failure and will void warranty Adding Hydraulic Oil 1 Make sure electric motor is OFF 2 Depressurize and disconnect hydraulic hose from application Sy...

Страница 7: ...Eccentric 5 8 Shaft 1 7 622 6 0318 100 Bearing 1 8 E05 6 9007 107 Sleeve Eccentric Bearing 1 9 a E05 4 4000 106 Piston Manifold 2 10 511 7 0064 109 O ring D6 4x1 8 2 11 E05 4 5000 101 Lower Plate Assembly 1 12 E05 4 2000 106 Oil Cap 1 13 649 1 0060 407 Bolt M6x1x 25 10 14 601 3 0064 106 Washer D11xD6 4x1T 10 15 b PW4 Control Valve 4 way 1 16 649 1 0095 204 Socket Head Screw 4 3 8 16UNCx1 17 c E05 ...

Страница 8: ...5 Hex Head Bolt 4 1 4 20UNCx2 1 2 19 d E10 4 6000 109 Gear Pump Assy 1 20 H23 6 1000 102 Magnet 1 21 E10 3 9005 108 Reservoir 1 22 E05 3 9901 103 Drain Plug Assembly 1 23 E10 6 6005 101 Filter 1 24 PEW01 Remote Pendant 1 a E05 3 9940 102 Seal Kit for Item 9 b E05 3 9911 106 Seal Kit for Item 15 c E05 3 9980 105 Seal Kit for Item 17 d E05 3 9960 109 Seal Kit for Item 19 F01 BVA Hydraulic Oil 1 gal ...

Страница 9: ...Cx1 17 E05 4 8000 106 Manifold Safety Valve 1 18 658 1 0064 305 Hex Head Bolt 4 1 4 20UNCx2 1 2 19 d E15 4 6000 104 Gear Pump Assy 1 20 H23 6 1000 102 Magnet 1 21 E15 3 9005 103 Reservoir 1 22 E05 3 9901 103 Drain Plug Assembly 1 23 E10 6 6005 101 Filter 1 24 PEW01 Remote Pendant 1 a E15 3 9940 101 Seal Kit for Item 9 b E05 3 9911 106 Seal Kit for Item 15 c E05 3 9980 105 Seal Kit for Item 17 d E1...

Страница 10: ... 1 4 20UNCx2 1 2 19 d E15 4 6002 108 Gear Pump Assy 1 20 H23 6 1000 102 Magnet 1 21 E30 3 9005 104 Reservoir 1 22 532 3 0160 104 Drain Plug Washer 1 23 E05 6 8008 104 Drain Plug 1 24 E10 6 6005 202 Filter 1 25 PEW01 Remote Pendant 1 a E15 3 9940 101 Seal Kit for Item 9 b E05 3 9911 106 Seal Kit for Item 15 c E05 3 9980 105 Seal Kit for Item 17 d E15 3 9960 107 Seal Kit for Item 19 F01 BVA Hydrauli...

Страница 11: ...104 Eccentric 5 8 Shaft 1 7 622 6 0318 100 Bearing 1 8 E05 6 9007 107 Sleeve Eccentric Bearing 1 9 a E30 4 4000 105 Piston Manifold 2 10 511 7 0064 109 O ring D6 4x1 8 2 11 E30 4 5000 100 Lower Plate Assembly 1 12 E10 4 2000 109 Vent Cap 1 13 649 1 0060 407 Bolt M6x1 25mm 10 14 601 3 0064 106 Washer D11xD6 4x1T 10 15 b PW4 Control Valve 4 way 1 16 649 1 0095 204 Socket Head Screw 4 3 8 16UNCx1 17 ...

Страница 12: ...SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 E mail sales bvahydraulics com 12 ...