BVA PA1500M Скачать руководство пользователя страница 4

4

Port A                  Port B

Port A                  Port B

Port A                  Port B

Position 1:

 Pressurized oil 

flows to port “B”, port “A” 

returns flow to tank.

P                      T

P                      T

P                      T

Position 2:

 Neutral, portss 

“A” and "B" are closed. Hold 

Position.

Position 1:

 Pressurized oil 

flows to port “A”, port “B” 

returns flow to tank.

1

2

3

Port A                                                                   Port B

Figure 2 - Flowpath of the valve positions and operations

OPERATION 

        To reduce the risk of personal injury and/or property

damage, Hydraulic connections must be securely fastened 

before building pressure in the system. Release all system 

pressure before loosening any hydraulic connection in the 

system.

         Always monitor pressure, load or position using 

suitable equipment. Pressure may be monitored by means of 

an optional manifold and gauge. Load may be monitored by 

means of a load cell and digital indicator. Correct application 

position  can  only  be  determined  by  the  operator  of  the 

equipment.

1. Connect air supply to the 1/4” NPT air nipple.

2. Remove manifold plug, connect to hydraulic hoses and 

suitable application.  

3. Shift the valve to desired position. There are three positions 

available, refer to Figure 2 on below for the flowpath.

4. After shifting the valve, press on the foot pedal until desired 

pressure,  load  or  position  is  reached.  Always  monitor 

pressure,  load  or  position  using  suitable  equipment. 

Pressure  may  be  monitored  by  means  of  optional 

manifolds  and  gauges  (contact  BVA  Hydraulics).  Load 

may be monitored by means of a load cells and digital 

indicators. 

Note. Do not continue to operate pump after cylinder plunger 

is fully extended or retracted.
5. Release the foot pedal will stop the pump flow.

Note: 

Both  air  input  ports  use  a  1/4  NPT  air  nipple  (not 

included).  It  is  recommended  to  install  an  inline  air  filter 

upstream  from  the  pump  to  provide  clean,  lubricated  air. 

Contact BVA Hydraulics for necessary accessories.

 

!

 

!

BEFORE USE

1.  Before  using  this  product,  read  the  instruction  manual 

completely  and  familiarize  yourself  thoroughly  with  the 

product and the hazards associated with its improper use.

2. Know your pump, its limitations and how it operates before 

attempting to use.

3. Replace shipping plug (red color) with air vent plug (black 

color)  before  use.  Refer  to  item  #68  on  Service  Parts 

Sheet.

4. Remove plastic cap from the air inlet port on the end of the 

pump, then connect with a 1/4”NPT air nipple (not supply 

with pump). Use teflon tape or similar thread sealant on 

thread connection.

Note:

 When using the teflon tape or pipe thread compound. 

Tighten securely to prevent accidental removal of compound 

while in use. Take care not to introduce compound into port 
orifices. 

Содержание PA1500M

Страница 1: ...l 888 332 6419 Fax 816 891 6599 E mail sales bvahydraulics com Website www bvahydraulics com Maximum Operating Pressure 10 000 PSI PA1500M M0 rev 08 07 This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death ...

Страница 2: ...rom service immediately until checked out by a BVA Hydraulics authorized service center Owners and operators of this equipment shall be aware that the use and subsequent repair of this equipment may require special training and knowledge PRODUCT DESCRIPTION BVA Hydraulics Double Acting Air Hydraulic Pump is engineered to meet most industrial standards for Performance and Safety It is an air hydrau...

Страница 3: ...r attach ANY component not authorized by manufacturer Always ensure that the chosen application is stable to work on and around Do not connect to application which can return more oil to the reservoir than the pump reservoir can hold Do not connect pump to hydraulic system powered by another pump This device is not suitable for use as support device As the system load is lifted use blocking and cr...

Страница 4: ...pressure load or position is reached Always monitor pressure load or position using suitable equipment Pressure may be monitored by means of optional manifolds and gauges contact BVA Hydraulics Load may be monitored by means of a load cells and digital indicators Note Do not continue to operate pump after cylinder plunger is fully extended or retracted 5 Release the foot pedal will stop the pump fl...

Страница 5: ...per level Poor performance Fluid level in pump is low Ensure proper fluid level 5 MAINTENANCE Important Use only a good quality hydraulic jack fluid Never use brake fluid transmission fluid turbine oil motor oil alcohol glycerin etc Use of other than good quality hydraulic oil will void warranty and damage the pump hose and application We recommend Mobil DTE 13M or equivalent 1 Inspect hoses and conne...

Страница 6: ...nd position in the assembly sequence Note To ensure safe and reliable performance replace worn or damaged parts with BVA Hydraulics Authorized Replacement Parts only MODEL PA1500M Air Hydraulic Pump Service Parts SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 Fax 816 891 6599 E mail sales bvahydraulics com Website www bvahydraulics com ...

Страница 7: ...on spring 1 32 A17 5 1603 300 Relief valve screw 1 33 601 7 0008 009 Steel ball 1 34 A59 6 1015 108 Oil entrance valve 1 35 520 8 0134 101 Filter 1 36 Gasket 1 37 A57 6 1601 107 Oil reservoir 1 38 649 1 0060 122 Allen screw 4 Item Part Number Description Qty 39 A57 6 1002 105 End plate air motor 1 40 A17 6 2105 108 Washer 2 41 A17 4 2100 500 Air motor piston 1 42 A57 6 1003 107 Cylinder air motor ...

Страница 8: ...VA Hydraulics product fails due to material defect in workmanship you may contact SFA for disposition In such cases the customer s sole and exclusive remedy for any breach or alleged breach of warranty is limited to the repair or replacement of the defective product Under no circumstances is BVA Hydraulics liable for any consequential or incidental damage or loss whatsoever THIS WARRANTY IS LIMITE...

Отзывы: