background image

• 

Study, understand, and follow all 

instructions provided with and on this 

device before use.

•  All WARNING statements must be 

carefully observed to help prevent 

personal injury.

  No alteration shall be made to this 

device.

 Always wear protective gear when 

operating hydraulic equipment.

  Keep hydraulic equipment away from 

flames and heat. Hydraulic fluid can 

ignite and burn. Do not operate if 

leaks are detected.

• 

Crush Hazard. 

Keep hands and feet 

away from loading area. Avoid pinch 

points or crush points that can be 

created by the load, cylinder, or any 

equipment of system.

• 

To avoid crushing and related injuries:

  NEVER work on, under or around 

a lifted load before it is properly 

supported by appropriate mechanical 

means. Never rely on hydraulic 

pressure alone to support load.

!

   

WARNING

HYDRAULIC PUMPS

•  The  user  must  be  a  qualified  operator  familiar  with  the 

correct operation, maintenance, and use of pumps. Lack of 

knowledge in any of these areas can lead to personal injury.

• Do not exceed rated capacity of the pump or any equipment 

in the system. 

• Never attempt to lift a load weighing more than the capacity 

of the cylinder. 

• Burst hazard exists if hose or connection pressure exceeds 

rated pressure.

• 

Inspect pump, cylinder, hoses and connections before each 

use to prevent unsafe conditions from developing. Do not 

use if they are damaged, altered or in poor condition. Do 

not operate the system with bent or damaged coupler or 

damaged threads.

•  Never  hold  or  stand  directly  in  line  with  any  hydraulic 

connections while pressurizing.

• 

Use gauge or other load measuring instrument to verify load. 

• Never attempt to disconnect hydraulic connections under 

pressure. Release all line pressure before disconnecting 

hoses.

•  Do  not  subject  the  pump  and  its  components  to  shock 

loads.

•  Use only approved accessories and approved hydraulic fluid.

• 

Never attach ANY component not authorized by manufacturer.

•  Always ensure that the chosen application is stable to work 

on and around.

• Do not connect to application  which can return more oil to 

the reservoir than the pump reservoir can hold. 

•  Do  not  connect  pump  to  hydraulic  system  powered  by 

another pump.

•  This device is not suitable for use as support device! As 

the system load is lifted, use blocking and cribbing to guard 

against a falling load.

•  All  personnel  must  be  clear  before  lowering  load  or 

depressurizing the system.

•  Never try to disassemble a hydraulic cylinder, refer repairs 

to qualified, authorized personnel.

HYDRAULIC HOSES & FLUID TRANSMISSION LINES

•  Avoid short runs of straight line tubing. Straight line runs 

do not provide for expansion and contraction due to 

pressure and/or temperature changes.

• Reduce stress in tube lines. Long tubing runs should be 

supported by brackets or clips.  Before operating the pump, 

tighten all hose connections with proper tools. Do not 

overtighten. Connections should only be tightened securely 

and leak-free. Overtightening can cause premature thread 

failure or high pressure fittings to burst.

• Should a hydraulic hose ever rupture, burst or need to be 

disconnected, immediately shut off the pump and release 

all pressure. Never attempt to grasp a leaking pressurized 

hose with your hands. The force of escaping hydraulic fluid 

can inflict injury.

• Do not subject the hose to potential hazard such as fire, 

sharp objects, extreme heat or cold, or heavy impact.

•  Do not allow the hose to kink, twist, curl, crush, cut or bend 

so tightly that the fluid flow within the hose is blocked or 

reduced. Periodically inspect the hose for wear.

•  Do not pull, position or move setup by the hose.

•  Hose material and coupler seals must be compatible with 

hydraulic fluid used. Hoses also must not come in contact 

with corrosive materials such as battery acid, creosote-

impregnated objects and wet paint. Never paint a coupler 

or hose.

• FAILURE TO HEED THESE WARNINGS MAY RESULT IN 

PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.

3

 SPECIFICATIONS

Model

Pump Type

Usable

Oil

Capacity

(in

3

)

Pressure Rating

(psi)

Oil Displacement 

per Stroke (in

3

)

Operating

Force

(lbs)

Piston 

Stroke        

(in)

Mounting

Plate 

Holes Dis-

tance (in)

Weight            

(lbs)

1st 

Stage

2nd 

Stage

1st 

Stage

2nd 

Stage

ZP601S

Single-

speed

36.61

0.15

99.8

0.75

3.74

16.1

Содержание ZP601S

Страница 1: ...3 Tel 888 332 6419 Fax 816 891 6599 E mail sales bvahydraulics com Website www bvahydraulics com Maximum Operating Pressure 10 000 PSI ZP601S M0_112014 This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death ...

Страница 2: ...ety These lever operated pumps supply compressed hydraulic fluid to compatible applications i e rams presses spreaders compactors and crimping machines anywhere that 10 000 PSI of fluid pressure is needed Special skill knowledge and training may be required for a specific task and the product may not be suitable for all the jobs described above Unsuitable applications would include applications th...

Страница 3: ...to application which can return more oil to the reservoir than the pump reservoir can hold Do not connect pump to hydraulic system powered by another pump This device is not suitable for use as support device As the system load is lifted use blocking and cribbing to guard against a falling load All personnel must be clear before lowering load or depressurizing the system Never try to disassemble a...

Страница 4: ...ed personnel as needed Before repairs are made depressurize system by opening the release valve counterclockwise but no more than 2 full turns OPERATION WARNING ALWAYS monitor pressure load or position using suitable equipment Pressure may be monitored by means of an optional manifold and gauge Load may be monitored by means of a load cell and digital indicator Correct application position can onl...

Страница 5: ... pump with a protective cover TROUBLESHOOTING GUIDE The following information is intended as an aid in determining if problem exists Pumps should be repaired only by authorized BVA Service Center For repair service contact service center in your area Symptom Possible Causes Corrective Action Erratic application action Air in the system External leak Internal hydraulic leak Vent the system Tighten ...

Страница 6: ... Service Parts SFA Companies 10939 N Pomona Ave Kansas City MO 64153 Tel 888 332 6419 Fax 816 891 6599 E mail sales bvahydraulics com Website www bvahydraulics com Note To ensure safe and reliable performance replace worn or damaged parts with BVA Hydraulics Authorized Replacement Parts only 1 2 4 3 5 6 7 6 7 8 9 10 11 12 13 14 13 15 16 17 20 19 18 17 21 22 23 34 33 32 31 18 30 28 29 27 24 25 26 ...

Страница 7: ... 16 522 8 0127 016 Filter 1 17 601 7 0008 009 Steel Ball 2 18 601 7 0006 005 Steel Ball 2 19 426 6 1105 201 Bolt 1 20 D05 6 1001 106 Oil Plug 1 21 Valve seal 1 22 H54 4 2105 100 Release valve 1 23 N A Base 1 24 H54 3 2134 202 Reservoir 1 25 Bonded seal 1 26 H28 6 4404 106 Nut 1 27 324 4 1900 309 Oil Filler Screw 1 28 H18 5 4401 207 Screw Bar 1 29 532 8 0050 024 Filter 1 30 O ring 1 31 501 9 0085 2...

Страница 8: ... in accordance with the instructions or warnings provided with the product In the unlikely event that a BVA Hydraulics product fails due to material defect in workmanship you may contact SFA for disposition In such cases the customer s sole and exclusive remedy for any breach or alleged breach of warranty is limited to the repair or replacement of the defective product Under no circumstances is BV...

Отзывы: