SPECIFICATIONS
Model Number
Usable
Oil
Capacity
gal (L)
Pressure Rating
psi (BAR)
Output Flow Rate
in
3
/min (L/min)
Valve
Type
Valve
Function
Motor
(hp)
Weight
lbs (kg)
1st
Stage
2nd
Stage
1st
Stage
2nd
Stage
PU20DMP01B
1
600
10,000
122
33
2-way,
2-position
Advance/
Return
1.0
36.3
PU20DMP01C
2
SAFETY AND GENERAL INFORMATION
Save these instructions.
For your safety, read and understand the information contained within. The owner and operator shall
have an understanding of this product and safe operating procedures before attempting to use this product. Instructions and
safety information shall be conveyed in operator's native language before use of this product is authorized. Make certain that the
operator thoroughly understands the inherent dangers associated with the use and misuse of the product. If any doubt exists as
to the safe and proper use of this product as outlined in this factory authorized manual, remove from service immediately.
Inspect before each use.
It is recommended that, prior to each use, an inspection be done by qualified personnel and that any
missing or damaged parts, decals, warning / safety labels or signs be replaced with factory authorized replacement parts only. Any
pump that appears to be damaged in any way, is worn, leaking or operates abnormally shall be removed from service immediately
until such time as repairs can be made. Any pump that has been subjected to a shock load (a load dropped suddenly, causing
the system pressure to exceed 10,000 PSI), shall be removed from service immediately until checked by qualified personnel.
Owners and operators of this equipment shall be aware that the use and subsequent repair of this equipment does require special
training and knowledge.
PRODUCT DESCRIPTION
This Pump is engineered to meet most industrial standards for Performance and Safety. Its allows quick displacement of hy-
draulic fluid under no load conditions and easy pumping in loaded conditions. This electric hydraulic pump supplies compressed
hydraulic fluid to compatible
single acting applications ONLY.
Such applications include rams, presses, spreaders, compactors
and crimping machines, anywhere that 10,000 PSI of single acting fluid pressure is needed. Special skill, knowledge and training
may be required for a specific task and the product may not be suitable for all the jobs described above. Unsuitable applications
would include applications that call for a device to move, level or support persons, animals, hazardous materials, mobile homes/
dwellings in general, mirrors and/or plate glass, and/or to connect/secure hatches, components, etc. between bulkheads. The
user must make the decision regarding suitability of the product for any given task and assume the responsibility of safety for
himself/herself and others in the work area.
!
DANGER
TO AVOID ELECTROCUTION HAZARD:
• Owner, Operator must read, understand and follow all printed material provided with this device before use.
• Connect ONLY to properly grounded electrical source. Connect to GFI outlet ONLY! For use in dry locations.
• Avoid the use of extension cords. If necessary, for extension cords lengths up to 25 ft, use SJT-14X3 or heavier.
For cords up to 50 ft, use SJT-12X3 or heavier. For extension cord lengths up to 100 ft, use SJT-10X3 or heavier
NEVER use a 3 prong adapter.
• Do not operate this device in an explosive atmosphere or in the presence of conductive liquids.
Figure 1 - Typical Dump Pump
(PU20DMP01B Shown)
Control Valve
Electric Motor
Drain Plug
Reservoir
Power Cord
Oil Output
Ports
Vent Cap