background image

Quality since 1946

9049 Tyler Blvd. • Mentor, Ohio 44060

Phone (440) 974-8888 • Fax (440) 974-0165

Toll-Free Fax 800-841-8003 • buyersproducts.com

Installation Instructions

AS301  Air Shift Cylinder

The AS301 Air Shift Cylinder mounts to Buyers BPC1010-Series, Permco 640-Series, 

or Commercial C101-Series Dump Pump/Valve in place of the detent assembly.

4. 

 Remove four cap screws and 

slide end cap off spool. 

Do not 

remove O-ring from valve hous-

ing.

 Clean mounting face  

of valve housing and spool.

Disassembly

1.

  Using snap ring pliers,  

remove snap ring from valve 

spool.

2.

  Remove retaining ring from 

valve spool.

3.

  Remove detent cap, spring 

and ball from valve’s end cap.

Assembly

5. 

 Place large O-ring and spring 

retainer over valve spool with 

smaller diameter hole in retainer 

toward valve casting. Be sure  

O-ring in valve housing is prop-

erly seated.

6.

  Apply light coating of grease 

to small O-ring and carefully 

place it into large detent groove 

in valve spool.

If end cap has a wiper seal, clean spool. Wrap a layer of thin, clear 

tape over groove to prevent seal from catching in it when you  

remove cap. Remove tape before installing Air Shift Kit.

—Installation Instructions continued on back