background image

 

 

3.

 

The warranty period will be extended by the time for which the device is in warranty 
repair. If the repair finds no defects falling under the warranty, the device owner shall pay the costs 
of the servicing technician’s work. 

4.

 

The warranty servicing covers defects occurring during the warranty period demonstrably due to 
flawed design, flawed workmanship or inappropriate material. Such defects will be repaired by the 
manufacturer free of charge. Complaints shall be made by the user with the device manufacturer; the 
place of performance is the manufacturer’s registered office. 

5.

 

The warranty does not cover defects caused  by inexpert handling, overloading, use of wrong 
accessories, or interventions by unauthorised persons, natural wear and tear, or damage during 
transport. Recognised defects exclude damage occurring due to inadequate care of neglected 
maintenance, non-adherence to rules specified in the Manual, using the device for purposes for which 
it is not intended, and overloading the device, albeit temporarily. 

6.

 

The warranty expires if the user makes any unpermitted modifications or changes to the device, 
connects the device wrongly, or has used the device in contravention of technical requirements .  

7.

 

The manufacturer is under no circumstances liable for subsequent damage caused by using the device. 
This warranty does not under any circumstances constitute the manufacturer’s liability in excess of 
the price of the device. 

8.

 

Device maintenance and repairs have to use exclusively original parts supplied by the manufacturer 
in accordance with their respective instructions for use. 
 

 

 

6.1

 

UNPACKING AND FIRST START 

1.

 

Unpack the device and any accessories supplied and check that they are in good order and the device 
and the accessories are not damaged. If you find any defects, do not continue ! 

2.

 

Leave the device to acclimatise for 15 minutes. 

3.

 

Remove the sealing ring located under the coolant tank filling hole lid tab. Pull to remove the lid tab 
and take out the sealing O-ring. Then push the tab, including the foam gasket, back into the tank lid. 
Keep the O-ring for potential future use if sending the machine via a parcel service. 

4.

 

If the focusing head is not attached to the grip by default, screw it on.   

5.

 

Fill the device with the coolant supplied with the device via the filling hole. 

6.

 

Connect the device to a 230V socket and turn it on using the switch at the back of the device .  

7.

 

The cooling circuit venting is activated automatically, and the letters “FIL” flash on the display during 
this. The coolant level decreases noticeably during the filling . 

8.

 

After completion of the venting, turn the device off and add the coolant so that the coolant level is at 
the upper edge of the gauge at the back of the device (about 1 cm below the top of the tank). 

9.

 

Turn on the device and let the venting proceed. If the level does not sink, the device is filled and vented 
correctly. Repeat the procedure as needed. 
 
 
 
 

Содержание DHI-44LKW

Страница 1: ...www buttsofbawtry com Tel 01302 710868 info buttsofbawtry com EN INDUCTION HEATER DHI 44LKW Operating and Maintenance Manual...

Страница 2: ...DUCTOR EXTENDER REPLACEMENT PROCEDURE 10 8 ABOUT THE DEVICE AND HEATING 10 8 1 SUPPORTED TECHNOLOGIES 10 DHCS3 Dawell Heating Control System 2 10 DIPA Dynamic Induction Power Adjust 11 8 2 HEATING MOD...

Страница 3: ...3 22 WARRANTY CERTIFICATE 23...

Страница 4: ...to repair your DHI 44E LKW The device contains no user reparable components The user is responsible for the system installation and use in accordance with instructions shown in this Manual The suppli...

Страница 5: ...notifications and follow the instruction shown below You will find more safety instructions in bellow SYMBOL EXPLANATION Risk of death by electrocution CAUTION Hot surface Risk of burns SYMBOL EXPLANA...

Страница 6: ...coil if it is activated and the strong magnetic field and heating are turned on ALWAYS wear protective gloves or other protections when handling the device as there is a risk of burns Protective equip...

Страница 7: ...dy parts and the heated inductor as specified in its instructions for use Short term tissue exposure to high intensity time variable magnetic field may lead to tissue warming by the induced current Lo...

Страница 8: ...ember to connect the yellow and green earthing wire before screwing it on 5 After maintenance carry out safety measurements as per standards in force Note Never use solvents or thinners e g acetone be...

Страница 9: ...ces constitute the manufacturer s liability in excess of the price of the device 8 Device maintenance and repairs have to use exclusively original parts supplied by the manufacturer in accordance with...

Страница 10: ...ion through the entire replacement procedure 4 Unscrew the heating inductor extender by rotating it counterclockwise until it is released 5 Make sure the threads and contact surfaces of both the grip...

Страница 11: ...ly it allows finer and sensitive heating e g in car repairs warming window edges when removing windows bodywork plates for easier removal of stickers rubber parts etc Advantages Power control by movin...

Страница 12: ...OF DEVICE COMPONENTS PoS Description Pos Description 1 USB connector 5 Indicator REMOTE 2 Display 6 Control indicator 3 Heating indicator 7 Indicator TIMER 4 Cooling and overheating indicator 8 Encod...

Страница 13: ...ice detects lack of coolant it displays the error message E12 In that case refill the coolant in the tank If everything is in order the device switches to standby Position Description 14 Main switch 1...

Страница 14: ...heating timer etc Note If the power is controlled remotely the letters rc are displayed for 3 sec when turning the encoder Indicator lamp Status Red Heating power setting in mode CP Red flashing Powe...

Страница 15: ...stepless Field control CF mode 30 100 stepless Lenght of induction torch 2 m Input power P1 max 3 5 kW Output induction power P2 max 3 7 kVA Dimensions 240x200x440 Mm Weight 11 5 Kg Coolant content 2...

Страница 16: ...18 2016 and 117 2016 sb verified by the compliance with the standard listed below Persuant to directive 2014 35 EU Low voltage SN EN 60519 1 ed 4 2015 IEC 60519 1 2015 SN EN 60519 3 ed 2 2006 IEC 6051...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Страница 21: ...e company is registered in the ASEKOL collective system under manufacturer registration no 04499 16 ECZ and finances handling of electrical waste itself This symbol on products and or in accompanying...

Страница 22: ...ta on the machine date of purchase serial number machine type If the information is not in accordance with the conditions for the recognition of warranty repairs for example Condition warranty imprope...

Страница 23: ..._________________________________ Seller s signature and stamp _______________________________________________________ Record of servicing intervention made Date of acceptance of servicing Date of rep...

Отзывы: