29
EN
BÜTTNER ELEKTRONIK – MT iQ Solar
Pro
Reset of cumulated solar charge power in Ah
The display for solar charge in Ah is used to determine the
total solar power over a certain period of time. The follo-
wing instructions explain how this cumulated performance
can be reset again.
Press the push-button
u
until the reset of “solar charge Ah”
is completed / Select RESET 0 Ah.
Keep the push-button
u
pressed until the progress bar rea-
ches at the end and “OK” is displayed. “Reset to 0 Ah” is done.
Reset / zero calibration of current sensor
“RESET 0.0A” is only needed if absolutely no current flow
through the sensor is present, but the display deviates from
0.0 A!
Select “RESET 0.0 A”: Ensure by pulling-out the fuse on the
solar controller that no solar charge current runs through
the sensor to the battery! Keep push-button
u
pressed
until the progress bar reaches at the end and “OK” is
displayed. Reset on 0.0 A is proceeded and a new value
becomes stored permanently.
Deactivate / activate displaying voltage:
If another voltage indication, e.g. battery computer MT iQ
Basic
Pro
is installed, the voltage indicator should be be
disabled on the MT iQ Basic
Pro
, so that the devices do not
influence each other negatively.
Click on this menu item with the push-button
u
and then
keep the button pressed for 5 seconds.
Menu now changes to the setup of the voltage display.
Each key-press changes the state from ON to OFF or vice
versa. If no key is pressed for 10 seconds the adjustment of
the values and the menu will be quit.