Appendix B
Electrical
Drawings
Page B-16
Figure B-16:
The Base Control Board (p/n 9102380A)
Indicates that a RUN Signal is
applied to the Machine’s RUN
Relay:
Lit = Machine is running
Off = Machine is stopped
Indicates that a STOP Pulse is
sent to other Equipment:
Lit =
NO
Pulse is sent
Off = Pulse is being sent
Indicates that a START Pulse is
sent to other Equipment:
Lit = Pulse is being sent
Off = No Pulse is sent
Connections to/from an
Upstream Machine
Connections to/from a Downstream Machine
Run/Stop Control for a
Friction Feeder
Connection to optional
Speed Control Board
Outputs to Run and Stack
Relays
Configuration DIP Switches
Power Connector
Connection to Front Panel Controls
STOP Input from a
Conveyor
Indicates that Power is
applied to Board
Indicates that a START Input is
received.
Lit = Input Received
Off = No Input
Indicates that a STOP Input is
received
Lit = Input Present
Off = No Input
Sensor Connections
JAM Response Configuration Jumper
Connections to Control Computer
Buskro Ltd.
BK730-2 Tabber
Содержание BK730-2
Страница 1: ...BK730 2 Tabber 2 Part No 9104528 User s Guide V1 2 ...
Страница 5: ...General Information Buskro Ltd BK730 2 Tabber Chapter 1 1 0 General Information ...
Страница 14: ...BK730 2 Base Buskro Ltd BK730 2 Tabber Chapter 2 2 0 BK730 2 Base ...
Страница 41: ...Mechanical Adjustments Buskro Ltd BK730 2 Tabber Chapter 3 3 0 Tabber Labeler Head BK731 2 ...
Страница 58: ...User Interface Buskro Ltd BK730 2 Tabber Chapter 4 4 0 User Interface ...
Страница 82: ...Appendix A Assembly Drawings Page A 3 Figure A 2 Tabber Skidbar Assembly 330740A Buskro Ltd BK730 2 Tabber ...
Страница 125: ...Appendix A Assembly Drawings Page A 46 Figure A 38 Tabber Base Mechanical Assembly 330730A Buskro Ltd BK730 2 Tabber ...