6.7 Engine
Failure on Take-off
1.
If there is sufficient runway land straight ahead
2.
If below 200 ft. AGL pick a landing spot 10 degrees to the right or left of straight ahead. Do
not attempt a 180 degree turn
3.
If above 200 ft. AGL, execute a gentle turn and pick the most suitable spot for a power off
landing
4.
If enough altitude permits, switch fuel tanks and attempt to restart the engine
6.8
Engine failure in Flight
1.
If enough altitude permits, switch fuel tanks and attempt to restart the engine
2.
If engine restart fails, make emergency radio calls as required
3.
Switch off electrics
4.
Turn fuel selector to OFF
5.
Pick a suitable landing spot and execute a power off landing
6.9
Power off Landing
1.
Trim aircraft for best gliding airspeed (58 mph)
2.
Pick a suitable field
3.
Make emergency radio calls as required
4.
Switch off electrics
5.
Turn fuel selector to OFF
6.
Land at lowest possible airspeed