8
Installation of your oven
It is required to call the authorized service to be able to
make the gas connections appropriately and in
compliance with safety standards.
Surely do not use any match or
lighter for control of gas leakage
ATTENTION!
.
Adapter
Gas Pipe
Gas Pipe
Seal
Seal
Hose
Fitting
Gas Hose
with Collar
Mechanical
Gas Hose
Gas Pipe
Gas Pipe
Seal
Mechanical
Gas Hose
Mechanical
Gas Hose
!
For all surfaces between different components,
always use the seals provided in the gas conversion
kit. The seals used during connection should also be
approved to be used in gas connections. Do not use
plumbing seals for gas connections.
Remember that this appliance is ready to be
connected to gas supply in the country for which it
has been produced. The main country of destination
is marked on the rear cover of the appliance. If you
need to use it in another country, any of the
connections in the figure below can be required. In
such a case,
learn the appropriate connection parts
and obtain those parts to perform a safe connection
.
Gas connection
Assembly of gas supply and leakage check
The connection of the appliance should be performed
in accordance with local and international standards
and regulations applicable. You can find the
information related to appropriate gas types and
appropriate gas injectors on technical data table. If the
pressure of used gas is different than these values
stated or not stable in your area,
it may be required to
assemble an available
pressure regulator on the gas
inlet. It is certainly required to contact to the
authorized service to make these adjusments.
The points that must be checked during flexible hose
assembly
If the gas connection is made by a flexible hose that is
fixed on the gas inlet of appliance, it must be fixed by
a pipe collar as well. Connect your appliance with a
short and durable hose that is as close as possible to
the gas source. The hose's permitted maximum lenght
is 1.5m. The hose that brings gas to the appliance
must be changed once a year for your safety.
The hose must be kept clear from areas that may heat
up to temperatures in excess of 9
0
°
C.
The hose must
not be ruptured, bent or folded. It must be kept clear
of sharp corners, moving things, and should not be
defective. Before assembly, it must be checked
whether there is any production defect.
As gas is turned on, all connection parts and hose
must be checked with
soapy
water or leakage fluids.
Do not use naked flame to check gas leakage. All metal
components used during gas connection must be
clear of rust. Also check the expiry dates of
components to be used.
The points that must be checked during fixed gas
connection assembly
To assemble a fixed gas connection (gas connection
made by threads, e.g. a nut), there are different
methods used in different countries. The most
common parts are already supplied with your
appliance. Any other part can be supplied as spare
part.
During connections always keep the nut on the gas
manifold fixed, while rotating the counter-part. Use
spanners of appropriate size for safe connection.
Figure 6
Figure 7