Troubleshooting (Continued)
Problem
Cause
Correction
Leaky valve
Paint on valve spool; sticking
(cont.)
valve spool or scored valve spool Instead, the plug and fitting should be
removed from valve body and be
reconnected, using a new O-ring. Do not
apply excessive pressure on mounting
bolts. The rods for CBH70, CBH80 should
be torqued to 14 ft/lbs for 5/16” nuts and 33
ft/lbs for 3/8” nuts. Never force spool.
Ball in anti-cavitation check
Clean anti-cavitation valve carefully, being
valve is stuck or not seating
sure that checks move freely and seat
properly.
properly, or replace cartridge.
Sticky valve spool
Paint on valve spool; sticking
Clean valve spool. Binding is usually
spool in
valve spool or scored valve
caused from an overtightened plug,
spool
mounting bolt, fitting in valve body or
tie rod bolt. If a plug or fitting in the valve
body is leaking, do not overtighten in an
effort to stop leak. This will distort body
casting and cause spools to bind. Instead,
the plug and fitting should be removed
from valve body and be reconnected,
using a new O-ring. Do not apply exces-
sive pressure on mounting bolts. The rods
for CBH70, CBH80 should be torqued to 14
ft/lbs for 5/16” nuts and 33 ft/lbs for 3/8”
nuts. Never force spool.
Bent spool
Replace with new spool section.
Foreign particles
Clean system and valve.
Misalignment of control handle
Check linkage for binding condition
linkage
Unable to push valve
Paint on valve spool; sticking
Clean valve spool. Binding is usually
spool in
valve spool or scored valve
caused from an overtightened plug,
spool
mounting bolt, fitting in valve body or
tie rod bolt. If a plug or fitting in the valve
body is leaking, do not overtighten in an
effort to stop leak. This will distort body
casting and cause spools to bind. Instead,
the plug and fitting should be removed
from valve body and be reconnected,
using a new O-ring. Do not apply exces-
sive pressure on mounting bolts. The rods
for CBH70, CBH80 should be torqued to 14
ft/lbs for 5/16” nuts and 33 ft/lbs for 3/8”
nuts. Never force spool.
Oil leakage past spool seal into
Remove cap. If it contains oil replace spool
spool cap
seal O-rings. Check O-ring retainer to be
sure it is flat. If it has been “belled” check
for restriction from outlet to reservoir of
valve which would cause excessive back
pressure. If supply and return lines are
reversed, pressure on low pressure / return
side of valve will cause problem.
Make sure hoses are connected correctly
at bulkhead connection on backhoe.
23
All manuals and user guides at all-guides.com
Содержание CBH60
Страница 54: ...All manuals and user guides at all guides com...
Страница 55: ...All manuals and user guides at all guides com...