![BUSCH SIMPLEX VO 0040 B Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/busch/simplex-vo-0040-b/simplex-vo-0040-b_operating-instructions-manual_2833492032.webp)
9 | Troubleshooting
32
/ 52
0870S03254
_VO 0040-0080_B_-0000_IM_en
9.3
41B
Resetting error
CAUTION
Danger due to accidental starting of the vacuum pump!
The vacuum pump may start up independently after error reset.
Make sure that starting the vacuum pump does not lead to a dangerous situation.
An error is signaled when the LED “FLT” lights up (see LED display
(fig. 10) and, if connected, by the lack of a ready-for-operation signal (terminal 20 of the con-
trol unit).
•
Before resetting an error, determine and remove its cause.
•
Reset the error by disconnecting and reconnecting the power supply for at least 10 seconds
or a digital signal at the terminal 10 of the control unit.
Содержание SIMPLEX VO 0040 B
Страница 2: ...2 52 0870S03254_VO 0040 0080_B_ 0000_IM_en ...
Страница 50: ...50 52 0870S03254_VO 0040 0080_B_ 0000_IM_en ...
Страница 51: ...Notes ...