Maintenance 

Prior to disconnecting connections make sure that the connected
pipes/lines are vented to atmospheric pressure

Maintenance Schedule 

Note

: The maintenance intervals depend very much on the individual 

operating conditions. The intervals given below are upper limits that 
must not be exceeded. 
Particularly heavy-duty operation, such like high dust loads in the en-
vironment or in the process gas, other contaminations or ingress of 
process material, can make it necessary to shorten the maintenance in-
tervals significantly. 

Every Year: 

Make sure that the vacuum pump is shut down and locked
against inadvertent start up

Make sure that the surface of the vacuum pump is free from dust
and dirt, clean if necessary

Blow out the drive motor lantern, ventilation slots and the cou-
pling with pressurised air

Remove the drive motor (a) from the motor lantern

Remove the motor lantern (1)

Clean the coupling hubs (2)(3) and the coupling element

Check that the coupling hubs (2)(3) are firmly seated

Check the coupling element for cracks and for a free of clearance
seated, replace the complete coupling if necessary.

In case of replacing the coupling: 

Slide the new coupling hub (2) onto the shaft of the vaccum
pump up to the stop

Tighten the clamping screw (4) with Loctite 243 and tighten
with 2 Nm

Slide the new coupling hub (3) onto the motor shaft up to
the stop

Secure the clamping screw (4) with Loctite 243 and tighten
with 2 Nm

Insert the new coupling element

Remount the motor lantern (1)

Remount the drive motor (a)

Check the electrical connection

Make sure that the earth cable (cable between earth connec-
tion (e) of the vacuum pump and earth point) is undamaged (re-
sistance check)

Every 5000 Operating Hours: 

Replace the vanes (

 page 8: Replacement of Vanes)

Every 2 Years: 

Check and clean the flame arrestors (d)(h) - in case of discoloura-
tion or deformation consult Busch or the manufacturer of the
flame arrestor in any case

Every 10000 Operating Hours, At the Latest after 
5 Years: 

Have a major overhaul on the vacuum pump (Busch service)

 WARNING 

The approval of the vacuum pump for use in potentially explo-
sive areas remains valid only if the maintenance is conducted 
regularly according to the maintenance schedule below and gen-
uine spare parts and consumables, approved for use in poten-
tially explosive areas by Busch, are used exclusively. 

Maintenance work must be executed by qualified personnel, 
specially instructed in the maintenance of this type of vacuum 
pump by Busch. 

 DANGER 

In case the vacuum pump conveyed gas that was contaminated 
with foreign materials which are dangerous to health, harmful 
material can reside in filters.

 

Danger to health during inspection, cleaning or replacement of 
filters.

 

Danger to the environment.

 

Personal protective equipment must be worn during the handling 
of contaminated filters.

 

Contaminated filters are special waste and must be disposed of 
separately in compliance with applicable regulations. 

 CAUTION 

During operation the surface of the vacuum pump may reach 
temperatures of more than 70 °C. 

Risk of burns! 

 

WARNING 

The proper assembly of flame arrestors is essential for their safe 
function. 

Risk of explosion in case of faulty assembly! 

Flame arrestors must only be serviced by personnel that have re-
ceived specific training for this purpose either by Busch or by the 
manufacturer of the flame arrestors. 

Содержание Seco SG 0008 A

Страница 1: ...llation and Operating Instructions Vacuum Pump Seco SG 0008 A with 3 Phase Motor Busch Produktions GmbH Schauinslandstr 1 79689 Maulburg Germany 0870162612 190709 Original instructions Modifications reserved ...

Страница 2: ...n Industry 20 Preface Congratulations on your purchase of the Busch vacuum pump With watchful observation of the field s requirements innovation and steady development Busch delivers modern vacuum and pressure solu tions worldwide These operating instructions contain information for product description safety transport storage installation and commissioning maintenance overhaul troubleshooting and...

Страница 3: ...ve atmospheres is valid for the vacuum pump together with the described measurement and safety equipment The approval is void if the system is altered or if the scheduled maintenance is not complied with Maintenance must be performed by specifically instructed personnel only Safety Concept The safety concept for the vacuum pump Seco SG 0008 A for use in potentially explosive atmosphere as a catego...

Страница 4: ...only by qualified personnel The allowed media and operational limits page 3 Product De scription and the installation prerequisites page 5 Installation Prerequisites of the vacuum pump shall be observed both by the manufacturer of the machinery into which the vacuum pump is to be incorporated and by the operator In particular the intended use in potentially explosive areas i e either inside the va...

Страница 5: ...Con formity Mounting Position and Space Make sure that the following ambient conditions will be complied with Ambient temperature range 30 50 C Ambient pressure atmospheric Make sure that the environmental conditions comply with the protection class of the drive motor IP54 If the machine is installed at an altitude greater than 1000 meters above sea level Contact your Busch representative the moto...

Страница 6: ...ional safety directives and the local or national regulations respectively are complied with this is the responsibility of the designer of the machinery into which the vacuum pump is to be incorporated page 13 note in the EU Declaration of Conformity Make sure that the power supply for the drive motor is compati ble with the data on the nameplate of the drive motor Make sure that a motor safety sw...

Страница 7: ...ed as zone 0 Outside the vacuum pump is approved as category 2 device for use in zone 1 According to the EC Type Examination Certificate issued by the German Physikalisch Technische Bundesanstalt PTB the vacuum pump may be used for the conveyance of explosive atmospheres con sisting of a mixture with air and flammable gases provided that the gases belongs to the temperature classes T1 to T3 and to...

Страница 8: ...sure that the earth cable cable between earth connec tion e of the vacuum pump and earth point is undamaged re sistance check Every 5000 Operating Hours Replace the vanes page 8 Replacement of Vanes Every 2 Years Check and clean the flame arrestors d h in case of discoloura tion or deformation consult Busch or the manufacturer of the flame arrestor in any case Every 10000 Operating Hours At the La...

Страница 9: ...f the vacuum pump involve no risk Dispose of the vacuum pump as scrap metal CAUTION The vanes 8 are self lubricating The vanes must by no means be lubricated with oil or grease DANGER Improper work on the vacuum pump puts the operating safety at risk Risk of explosion Approval for operation will be void Any dismantling of the vacuum pump that is beyond of what is described in this manual must be d...

Страница 10: ...ed Clean or replace the inlet air filter Long suction or discharge line with too small diameter Use larger diameter The vanes are worn Replace the vanes WARNING Vacuum pump for use in potentially explosive atmospheres Risk of explosion in case of operation of faulty equipment The vacuum pump must only be operated in faultless condition A faulty vacuum pump must immediately be removed from service ...

Страница 11: ... 6 Installation The drive motor is running but the vacuum pump stands still The coupling between the drive motor and the vacuum pump is defective Replace the coupling element Busch service The vacuum pump runs very hot thermal protection switch triggers Insufficient air ventilation Make sure that the cooling of the vacuum pump is not impeded by dust dirt Install the vacuum pump in a narrow space o...

Страница 12: ...ing Drive Virginia Beach VA 23452 Tel 1 800 USA PUMP 872 7867 Your point of contact for service and spare parts in Canada Busch Vacuum Technics Inc 1740 Boulevard Lionel Bertrand Boisbriand Montréal Québec J7H 1N7 Tel 450 435 6899 Fax 450 430 5132 Your point of contact for service and spare parts in Australia Busch Australia Pty Ltd 30 Lakeside Drive Broadmeadows Vic 3047 Tel 03 93 55 06 00 Fax 03...

Страница 13: ...nery General principles for design Risk assessment and risk reduction EN ISO 13857 Safety of machinery Safety distances to prevent hazard zones being reached by the upper and lower limbs EN 1012 1 EN 1012 2 Compressors and vacuum pumps Safety requirements Part 1 and 2 EN ISO 2151 Acoustics Noise test code for compressors and vacuum pumps Engineering method grade 2 EN 60204 1 Safety of machinery El...

Страница 14: ...Seco SG 0008 A page 14 0870162612 190709 EC Type Examination Certificate ...

Страница 15: ...Seco SG 0008 A 0870162612 190709 page 15 ...

Страница 16: ...Seco SG 0008 A page 16 0870162612 190709 ...

Страница 17: ...Seco SG 0008 A 0870162612 190709 page 17 ...

Страница 18: ...Seco SG 0008 A page 18 0870162612 190709 ...

Страница 19: ...Seco SG 0008 A 0870162612 190709 page 19 ...

Страница 20: ...0 e mail sales busch ie Israel Busch Israel Ltd 1 Mevo Sivan Street Qiryat Gat 82022 Israel Tel 972 0 8 6810485 Fax 972 0 8 6810486 e mail service_sales busch co il Italy Busch Italia S r l Via Ettore Majorana 16 20054 Nova Milanese Tel 39 0362 370 91 Fax 39 0362 370 999 e mail info busch it Japan Nippon Busch K K 1 23 33 Megumigaoka Hiratsuka City Kanagawa Japan 259 1220 Tel 81 463 50 4000 Fax 81...

Отзывы: