BUSCH Samos SB 0050 D0 Скачать руководство пользователя страница 11

The drive motor starter overload protection is
too small or trip level is too low

Compare the trip level of the drive motor
starter overload protection with the data on
the nameplate, correct if necessary

One of the fuses has blown

Check the fuses

The connection cable is too small or too long
causing a voltage drop at the side channel
blower

Use sufficiently dimensioned cable

The side channel blower or the drive motor is
blocked

Make sure the drive motor is disconnected
from the power supply

Remove the fan cover

Try to turn the drive motor with the side
channel blower by hand

If the side channel blower is blocked:

Repair the side channel blower (Busch service)

The drive motor is defective

Replace the drive motor (Busch service)

The side channel blower is blocked

Solid foreign matter has entered the side
channel blower

Repair the side channel blower (Busch service)

Make sure the suction line is equipped with a
screen

If necessary additionally provide a filter

Corrosion in the side channel blower from re-
maining condensate

Repair the side channel blower (Busch service)

Check the process

The side channel blower was run in the wrong
direction

Repair the side channel blower (Busch service)

When connecting the side channel blower
make sure the side channel blower will run in
the correct direction (

Ú

page 6: Installation)

The side channel blower starts, but labours or
runs noisily or rattles

The drive motor draws a too high current
(compare with initial value after commission-
ing)

Loose connection(s) in the drive motor termi-
nal box

Not all drive motor coils are properly con-
nected

The drive motor operates on two phases only

Check the proper connection of the wires
against the connection diagram

Tighten or replace loose connections

The side channel blower runs in the wrong di-
rection

Verification and rectification

Ú

page 5: Instal-

lation and Commissioning

Foreign objects in the side channel blower

Stuck bearings

Repair the side channel blower (Busch service)

The side channel blower runs very noisily

Defective bearings

Repair the side channel blower (Busch service)

The side channel blower runs very hot

Insufficient air ventilation

Make sure that the cooling of the side channel
blower is not impeded by dust/dirt

Clean the fan cowling, the fan wheel, the ven-
tilation grille and the cooling fins

Install the side channel blower in a narrow
space only if sufficient ventilation is ensured

Ambient temperature too high

Observe the permitted ambient temperatures

Temperature of the inlet gas too high

Observe the permitted temperatures for the
inlet gas

Insufficient gas transfer

Check the process conditions

Mains frequency or voltage outside tolerance
range

Provide a more stable power supply

Partial clogging of filters or screens

Partial clogging in the suction, discharge or
pressure line

Remove the clogging

Long suction, discharge or pressure line with
too small diameter

Use larger diameter

Troubleshooting

SB 0050 - 1400 D0/D2

ATEX-Version

0870145236

/

181122

page 11

Содержание Samos SB 0050 D0

Страница 1: ...and Operating Instructions Side Channel Blowers Samos SB 0050 1400 D0 D2 ATEX Version Busch Produktions GmbH Schauinslandstr 1 79689 Maulburg Germany 0870145236 181122 Original instructions Modificati...

Страница 2: ...chful observation of the field s requirements innovation and steady development Busch delivers modern vacuum and pressure solu tions worldwide These operating instructions contain information for prod...

Страница 3: ...y explosive gas atmospheres II 3G T3 Group II for non mining applications in the process gas and in the environment explosive atmosphere con sisting of a mixture with air of flammable substances in th...

Страница 4: ...se operating instructions highlight potential hazards where appropriate Safety notes are tagged with one of the keywords DANGER WARNING and CAUTION as follows DANGER_a Disregard of this safety note wi...

Страница 5: ...s carried out such that the essential safety requirements of the Machine Di rective 2006 42 EC are complied with in the responsibility of the designer of the machinery into which the side channel blow...

Страница 6: ...he length of the pressure line exceeds 2 m it is prudent to use larger line sizes in order to avoid a loss of efficiency and an overload of the side channel blower Seek advice from your Busch represen...

Страница 7: ...technische Kenngr en Band 1 Brennbare Fl ssigkeiten und Gase ISBN 3 89701 745 8 or equivalent source If the classifications with regard to the conveyed gas air or dust air mixture on the one side and...

Страница 8: ...ented to atmospheric pressure Maintenance SB 0050 1400 D0 D2 ATEX Version 0870145236 181122 page 8 The nominal value for the ambient temperature is 25 C The min al lowed ambient temperature is 30 C Th...

Страница 9: ...ated as special waste have been separated from the side channel blower Make sure that the side channel blower is not contaminated with harmful foreign material According to the best knowledge at the t...

Страница 10: ...Evacuation of the system takes too long Pressure operation Filling the system takes too long Building up pressure in the system takes too long Vacuum operation The vacuum system or suction line is no...

Страница 11: ...ttles The drive motor draws a too high current compare with initial value after commission ing Loose connection s in the drive motor termi nal box Not all drive motor coils are properly con nected The...

Страница 12: ...17 2102 RESTRICTION OF THE USE OF CERTAIN HAZARDOUS SUBSTANCES IN ELECTRICAL AND ELECTRONIC EQUIPMENT AND FOLLOWING THE STANDARDS 3TANDARD 4ITLE OF THE 3TANDARD 3 3AFETY OF MACHINERY q ASIC CONCEPTS E...

Страница 13: ...SB 0050 1400 D0 D2 ATEX Version 0870145236 181122 page 1...

Страница 14: ...SB 0050 1400 D0 D2 ATEX Version 0870145236 181122 page 1...

Страница 15: ...SB 0050 1400 D0 D2 ATEX Version 0870145236 181122 page 1...

Страница 16: ...66 Fax 00353 1 832 1470 Israel Busch Israel Ltd 1 Mevo Sivan Street Qiryat Gat 82022 Israel Tel 972 0 8 6810485 Fax 972 0 8 6810486 Italy Busch Italia S r l Via Ettore Majorana 16 20054 Nova Milanese...

Отзывы: