5 | Installation
20 / 40
0870572240_RA0400-0630C_Ex_-0011_IM_en
Warning signal:
T
warning
(TSA+/0101) = 145°C
►
19.46 mA (for RA/RC 0400 and 0502 C)
T
warning
(TSA+/0101) = 135°C
►
18.4 mA (for RA/RC 0630 C)
T
warning
(TSA+/0102) = 75°C
►
12 mA (for RA/RC 0400-0630 C)
T
warning
(for RA/RC 0400-0630 C)
Trip signal:
T
trip
(TSA+/0101) = 150°C
►
20 mA (for RA/RC 0400 and 0502 C)
T
trip
(TSA+/0101) = 140°C
►
18.93 mA (for RA/RC 0630 C)
T
trip
(TSA+/0102) = 80°C
►
12.53 mA (for RA/RC 0400-0630 C)
T
trip
(for RA/RC 0400-0630 C)
5.7.3 Wiring Diagram Pressure Switch
Part no.: 0653 539 030
Supplier reference: United Electric Controls
H100 (100 Series)
Maintenance procedure:
Procedure B
P&ID position: PS+/0301
Electrical data:
U
i
= 49 VDC ; I
i
= 3 A ; L
i
= 0 µH ; C
i
= 0 pF
Contact: Normally closed
2
1
P
Switch point: P (PS+/0301) = 1500 hPa (mbar) abs. (factory default adjustment)
5.7.4 Wiring Diagram Pressure Transmitter
Part no.: 0653 204 444
Supplier reference: Wika IS-3
Connector: M12x1, 4-pin
P&ID position: PSA+/0301
1
2
4
3
3
1
+
-
1 = Brown ; 3 = Blue
Electrical data:
U
i
= 30 VDC ; I
i
= 100 mA ; P
i
= 800 mW ; L
i
= 0 µH ; C
i
= 16.5 nF
4 ... 20 mA
►
0 ... 1.6 bar (abs.)
Warning signal:
P
warning
(PSA+/0301) = 1.4* bar
►
18 mA
*1400 hPa (mbar) abs.
Trip signal:
P
trip
(PSA+/0301) = 1.5* bar
►
19 mA
*1500 hPa (mbar) abs.
5.7.5 Wiring Diagram Level Switch
Part no.: 0652 556 531
Supplier reference:
Endress&Hauser FTL50/FEL58
Connector: M12x1, 4-pin
P&ID position: LS-/0201
1
2
4
3
4
1
L
1 = Brown ; 4 = Black
Electrical data:
U
i
= 16 VDC ; I
i
= 52 mA ; P
i
= 0.17 W ; C
i
= 0 nF