background image

3 | Product Description

6 / 12

0870524638_RA_Aqua_A0003_IMS_en

3.1 Application

The machine is intended for the suction of gases which contain a high percentage of wa-
ter vapour.
Other agents should not be transported. In case of doubt, please contact your Busch
representative.

3.2 Standard Accessories

3.2.1 Gas Ballast Valve

The gas ballast valve mixes the process gas with a limited quantity of ambient air to
counteract the condensation of vapour inside the machine.

The gas ballast of the Aqua version has a larger air volume flow than a standard R5.

The gas ballast valve has an influence on the ultimate pressure of the machine, see 

Tech-

nical Data [

 8]

.

3.2.2 Thermostatic Valve

It allows to fix a higher operating temperature than a standard R5.

3.2.3 Temperature Switch "Oil"

The temperature switch monitors the oil temperature of the machine.

It has two switch points.

Depending on the oil type, the machine must be stopped when the oil reaches a certain
temperature, see 

Oil [

 8]

.

3.3 Optional Accessories

3.3.1 Inlet Filter

The inlet filter protects the machine against dust and other solids in the process gas. The
inlet filter is available with a polyester cartridge.

3.3.2 Water Separator

It allows to retrieve a certain amount of condensate at the machine exhaust. It is
equipped with a drain plug at its bottom.

Содержание R5 Aqua

Страница 1: ...t R5 Aqua version Oil Lubricated Rotary Vane Vacuum Pumps RA 0165 D RA 0205 D RA 0255 D RA 0305 D RA 0400 C RA 0502 C RA 0630 C RA 1000 B RA 1600 B 0870524638 A0003_en Original instructions Modifications reserved 17 02 2021 Ateliers Busch S A Zone industrielle 2906 Chevenez Switzerland ...

Страница 2: ...Gas Ballast Valve 6 3 2 2 Thermostatic Valve 6 3 2 3 Temperature Switch Oil 6 3 3 Optional Accessories 6 3 3 1 Inlet Filter 6 3 3 2 Water Separator 6 4 Installation 7 4 1 Connecting Lines Pipes 7 4 1 1 Suction Connection 7 4 1 2 Discharge Connection 7 4 2 Electrical Connection of the Monitoring Devices 7 4 2 1 Wiring Diagram Temperature Switch Oil 7 5 Technical Data 8 6 Oil 8 ...

Страница 3: ...en designed and manufactured according to state of the art meth ods Nevertheless residual risks may remain This instruction manual highlights potential hazards where appropriate Safety notes and warning messages are tagged with one of the keywords DANGER WARNING CAUTION NOTICE and NOTE as follows DANGER indicates an imminent dangerous situation that will result in death or serious injuries if not ...

Страница 4: ... Introduction NOTE Instruction manual supplement This document is a supplement to the R5 instruction manuals which contents remain valid It contains additional information in the following chapters Product Description 5 Installation 7 and Technical Data 8 ...

Страница 5: ...0165 0305 D Aqua RA 0400 0630 C Aqua IN IF GB1 WS1 OUT1 GB2 WS2 OUT2 RA 1000 1600 B Aqua CD2 CD1 CD CD IN Suction connection IF Inlet filter OUT Discharge connection CD Condensate drain TS Temperature switch WS Water separator NOTE Illustrations In this instruction manual the illustrations may differ from the machine appearance ...

Страница 6: ... gas ballast valve has an influence on the ultimate pressure of the machine see Tech nical Data 8 3 2 2 Thermostatic Valve It allows to fix a higher operating temperature than a standard R5 3 2 3 Temperature Switch Oil The temperature switch monitors the oil temperature of the machine It has two switch points Depending on the oil type the machine must be stopped when the oil reaches a certain temp...

Страница 7: ...tion size s Ø60 mm hose for RA 0165 0305 D Ø90 mm hose for RA 0400 0630 C DN150 PN16 EN 1092 1 for RA 1000 1600 B The inlet connection may be equipped with a ball valve Depending on the specific order other connection dimensions may apply 4 1 2 Discharge Connection Connection size s G2 for RA 0165 0305 D G3 for RA 0400 0630 C 2x DN125 PN16 EN 1092 1 for RA 1000 1600 B Depending on the specific ord...

Страница 8: ...ing speed 50Hz 60Hz m h 630 760 1000 1200 1600 1800 Ultimate pressure hPa mbar abs 5 Water vapour tolerance max hPa mbar 100 Water vapour capacity DIN 28426 1 50Hz 60Hz kg h 50 60 89 160 99 160 6 Oil VSC 100 VSB 100 ISO VG 100 100 Oil type Synthetic oil Synthetic oil Part number 1 L packaging 0831 168 356 0831 168 351 Part number 5 L packaging 0831 168 357 0831 168 352 Part number 10 L packaging 0...

Страница 9: ...Note ...

Страница 10: ...Note ...

Страница 11: ...Note ...

Страница 12: ...t Japan info busch co jp Korea busch busch co kr Malaysia busch busch com my Mexico info busch com mx Netherlands info busch nl New Zealand sales busch co nz Norway post busch no Peru info busch com pe Poland busch busch com pl Portugal busch busch pt Romania office buschromania ro Russia info busch ru Singapore sales busch com sg South Africa info busch co za Spain contacto buschiberica es Sweden...

Отзывы: