11 | Troubleshooting
32 / 40
0870201062_RA1000-1600B_Ex_-0007_IM_en
11 Troubleshooting
DANGER
Live wires.
Risk of electrical shock.
• Electrical installation work must only be executed by qualified personnel.
CAUTION
Hot surface.
Risk of burns!
• Prior to any action requiring touching the machine, let the machine cool down first.
Illustration showing parts that may be involved during troubleshooting:
OF
CPL
GB
FV
IS
EF
GB
Problem
Possible Cause
Remedy
The machine does not start. The motor is not supplied
with the correct voltage.
• Check the power supply.
The motor is defective.
• Replace the motor.
The coupling (CPL) is de-
fective.
• Replace the coupling
(CPL).
The machine does not reach
the usual pressure on the
suction connection.
Oil level too low.
• Top up oil.
The inlet screen (IS) is par-
tially clogged.
• Clean the inlet screen (IS).
The inlet filter cartridge (op-
tional) is partially clogged.
• Replace the inlet filter
cartridge.
Internal parts are worn or
damaged.
• Repair the machine (con-
tact Busch).
The machine runs very nois-
ily.
Worn coupling (CPL).
• Replace the coupling
(CPL).
Stuck vanes.
• Repair the machine (con-
tact Busch).
Defective bearings.
• Repair the machine (con-
tact Busch).