7 | Maintenance
18 / 32
0870221625_MV0040-0080D_-0000_IM_en_MD
• After process:
• During process condensate may occur in the machine. To remove the condens-
ate from the machine convey dry air at 200-400 mbar with the machine’s max-
imum speed after the process. The condensate drain (CD-L) must be opened
constantly. The condensate drain (CD-R) must be opened for at least 1 minute.
NOTE
Condensate drains.
In case of very high condensate formation the condensate drain (CD-L) can re-
main open during the process. The opening of the condensate drain (CD-R)
leads to a strong increase of the noise level and is not necessary during the
process.
7
Maintenance
WARNING
Machines contaminated with hazardous material.
Risk of poisoning!
Risk of infection!
If the machine is contaminated with hazardous material:
• Wear appropriate personal protective equipment.
CAUTION
Hot surface.
Risk of burns!
• Prior to any action requiring touching the machine, let the machine cool down first.
NOTICE
Using inappropriate cleaners.
Risk of removing safety stickers and protective paint!
• Do not use incompatible solvents to clean the machine.
CAUTION
Failing to properly maintain the machine.
Risk of injuries!
Risk of premature failure and loss of efficiency!
• Respect the maintenance intervals or ask your Busch representative for service.
• Shut down the machine and lock against inadvertent start up.
• Vent the connected lines to atmospheric pressure.
If necessary:
• Disconnect all connections.