The level shall be slightly above the middle of the sight glass (g, 76).

Check on the sight glass (g, 76) that the proper amount of oil is
filled

Connecting Electrically

WARNING

_ab

Risk of electrical shock, risk of damage to equipment.

Electrical installation work must only be executed by qualified per-
sonnel that knows and observes the following regulations:
- IEC 364 or CENELEC HD 384 or DIN VDE 0100, respectively,
- IEC-Report 664 or DIN VDE 0110,
- BGV A2 (VBG 4) or corresponding national accident prevention
regulation.

CAUTION

_a

The connection schemes given below are typical. Depending on the
specific order or for certain markets deviating connection schemes
may apply.

Risk of damage to the drive motor!

The inside of the terminal box shall be checked for drive motor con-
nection instructions/schemes.

Electrically connect the drive motor

Connect the protective earth conductor

Delta connection (low voltage):

Star connection (high voltage):

CAUTION

_a

Operation in the wrong direction of rotation can destroy the
compressor in short time.

Prior to starting-up it must be made sure that the compressor is op-
erated in the proper direction.

Determine the intended direction of rotation with the arrow (a)
(stuck on or cast)

“Bump” the drive motor

Watch the fan wheel of the drive motor and determine the direc-
tion of rotation just before the fan wheel stops

If the rotation must be changed:

Switch any two of the drive motor wires

Electrically connect the motor (e) of the separate fan

Connecting Lines/Pipes

Connect the suction line

Installation without suction line:

Make sure that the gas inlet (b) is open

Connect the pressure line

Make sure that all provided covers, guards, hoods etc. are
mounted

Make sure that cooling air inlets and outlets are not covered or ob-
structed and that the cooling air flow is not affected adversely in
any other way

Recording of Operational Parameters

As soon as the compressor is operated under normal operating
conditions:

Measure the drive motor current and record it as reference for fu-
ture maintenance and troubleshooting work

Operation Notes

Use

CAUTION

_a

The compressor is designed for operation under the conditions de-
scribed below.

In case of disregard risk of damage or destruction of the compressor
and adjoining plant components!

Risk of injury!

The compressor must only be operated under the conditions de-
scribed below.

The compressor is intended for

the compression

of

air and other dry, non-aggressive, non-toxic and non-explosive
gases

Conveying media with a lower or higher density than air leads to an in-
creased thermal and/or mechanical load on the compressor and is per-
missible only after prior consultation with Busch.

Max. allowed temperature of the inlet gas: 40 °C

Standard-version:

The gas shall be free from vapours that would condensate under
the temperature and pressure conditions inside the compressor.

Version “Aqua”:

The compressor features the corrosion protection coating CPC and
is capable of conveying water vapour (

Ú

page 7: Conveying

Condensable Vapours). Conveyance of other vapours shall be
agreed upon with Busch. Conveyance of water or other liquids in
liquid phase increases the power consumption and shall therefore
be avoided (risk of drive overload).

The compressor is intended for the placement in a non-potentially ex-
plosive environment.

The compressor is thermally suitable for continuous operation
(100 percent duty).

Max. permissible number of startings per hour: 12

The maximum allowed pressure on the pressure connection (i) is
0.8 ... 2.0 barg (the nameplate of the compressor indicates the valid
pressure). By means of process control and/or pressure relief valves it

Installation and Commissioning

MI 1502 BP

page 6

0870152627 / 101117

Содержание Mink MI 1502

Страница 1: ...Installation and Operating Instructions Compressors Mink MI 1502 Busch Produktions GmbH Schauinslandstr 1 79689 Maulburg Germany 0870152627 101117 Original instructions Modifications reserved...

Страница 2: ...isposal 8 Troubleshooting 9 Sectional Drawing 12 Spare Parts 13 Spare Parts Kits 13 Oil 13 EC Declaration of Conformity 14 Technichal Data 15 Busch All over the World in Industry 16 Preface MI 1502 BP...

Страница 3: ...between the chambers low In order to avoid the suction of solids the compressor is equipped with a screen 715 in the gas inlet In order to avoid reverse rotation after switching off the compressor is...

Страница 4: ...flange etc Attach the lifting gear to a crane hook with safety latch Loosely hang the additional belt rope into the crane hook Lift the compressor with a crane In case the compressor was bolted to a p...

Страница 5: ...ocess gases and or adverse operating cycles bear the risk that condensates remain in the compressor Provide a shut off valve a drip leg and a drain cock in the suc tion line so that condensates can be...

Страница 6: ...or ob structed and that the cooling air flow is not affected adversely in any other way Recording of Operational Parameters As soon as the compressor is operated under normal operating conditions Mea...

Страница 7: ...ation chamber Maintenance DANGER_age32 In case the compressor conveyed gas that was contaminated with foreign materials which are dangerous to health harmful material can reside in filters Danger to h...

Страница 8: ...aterial can reside in pores gaps and internal spaces of the compressor Danger to health during dismantling of the compressor Danger to the environment Prior to shipping the compressor shall be deconta...

Страница 9: ...frequently install a filter upstream In case a filter b is installed on the gas inlet b The filter b on the gas inlet b is partially clogged Clean or replace the inlet air filter b respec tively Parti...

Страница 10: ...after commission ing Loose connection s in the drive motor termi nal box Not all drive motor coils are properly con nected The drive motor operates on two phases only Check the proper connection of th...

Страница 11: ...djusted or defective Adjust repair or replace respectively Partial clogging of filters or screens Partial clogging in the suction discharge or pressure line Remove the clogging Long suction discharge...

Страница 12: ...Sectional Drawing Sectional Drawing MI 1502 BP page 12 0870152627 101117...

Страница 13: ...any Auckland 1311 P O Box 302696 North Harbour Auckland 1330 Tel 0 9 414 7782 Fax 0 9 414 7783 Find the list of Busch companies all over the world by the time of the publication of these installation...

Страница 14: ...ardous substances in electrical and electronic equipment and following the standards Standard Title of the Standard EN ISO 12100 2010 Safety of machinery General principles for design Risk assessment...

Страница 15: ...E N I S O 2 1 5 1 w i t h s i l e n c e r d b A W e i g h t k g A m b i e n t t e m p e r a t u r e C A m b i e n t p r e s s u r e S y n c h r o n i s i n g g e a r o i l q t y l S y n c h r o n i s...

Страница 16: ...les busch ie Israel Busch Israel Ltd 1 Mevo Sivan Street Qiryat Gat 82022 Israel Tel 972 0 8 6810485 Fax 972 0 8 6810486 e mail service_sales busch co il Italy Busch Italia S r l Via Ettore Majorana 1...

Отзывы: