Installation | 5
Instruction Manual DOLPHIN LG 0890-2680 A, LR 0700-2200 A_EN_en
11 | 40
5
Installation
5.1
Installation Conditions
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
●
Take care that the installation conditions are fully complied with.
●
Make sure that the environment of the machine is not potentially explosive.
●
Make sure that the ambient conditions comply with the
●
Make sure that the environmental conditions comply with the protection class of the motor.
●
Make sure that the installation space or location is protected from weather and lightning.
●
Make sure that the installation space or location is vented such that sufficient cooling of the ma-
chine is provided.
●
Make sure that cooling air inlets and outlets of the motor fan are not covered or obstructed and
that the cooling air flow is not affected adversely in any other way.
●
Make sure that enough space remains for maintenance work.
●
Make sure that the machine is placed or mounted horizontally on a flat surface.
●
Make sure that the machine is connected to an operating liquid system, see
●
Make sure that all provided covers, guards, hoods, etc. are mounted.
In case of a machine delivery without motor:
●
Make sure that the coupling is correctly aligned, see
If the machine is installed at an altitude greater than 1000 meters above sea level:
●
Contact your Busch representative, the motor should be derated or the ambient temperature
limited.
5.2
Connecting Lines / Pipes
●
Remove all protective covers before installation.
●
Make sure that the connection lines cause no stress on the machine‘s connection; if necessary use
flexible joints.
●
Make sure that the line size of the connection lines over the entire length is at least as large as
the connections of the machine.
In case of long connection lines it is advisable to use larger line sizes in order to avoid a loss of effi-
ciency. Seek advice from your Busch representative.