6 | Commissioning
24 / 40
0870219588_NS0600C_WCV_Ex_-0000_IM_en
6
Commissioning
WARNING
The machine is still running after a monitoring device has tripped.
Risk of severe injury!
Risk of explosion!
• Follow the Trip Procedure.
NOTICE
The machine can be shipped without oil.
Operation without oil will ruin the machine in short time!
• Prior to commissioning, the machine must be filled with oil, see
.
NOTICE
The machine can be shipped without cooling liquid.
Operation without cooling liquid will ruin the machine in short time!
• Prior to commissioning, the machine must be filled with cooling liquid, see
.
NOTICE
Lubricating a dry running machine (compression chamber).
Risk of damage to the machine!
• Do not lubricate the compression chamber of the machine with oil or grease.
CAUTION
During operation the surface of the machine may reach temperatures of more than
70°C.
Risk of burns!
• Avoid contact with the machine during and directly after operation.
CAUTION
Noise of running machine.
Risk of damage to hearing!
If persons are present in the vicinity of a non noise insulated machine over extended
periods:
• Make sure that ear protection is being used.
• Make sure that the installation conditions (see
) are
met.
• Turn on the water supply.
Make sure that the machine does not contain a potentially explosive atmosphere. In case
of doubt, the machine must be purged by an inert gas.