7 | Commissioning
22 | 44
Instruction Manual COBRA NF 0750 A - NF 0950 A WCV_EN_en
7
Commissioning
WARNING
Lack of oxygen regulation knowledge.
Risk of fire!
●
Installation, commissioning, and maintenance must only be carried out by qualified personnel
who are informed about the applicable safety regulations and trained in the handling of oxygen.
●
Accident prevention regulations or methods must imperatively be complied with.
Seek further information:
- European Industrial Gases Association “EIGA” www.eiga.eu (EIGA SAG NL 79/04).
- Berufsgenossenschaft Rohstoffe und chemische Industrie "BG RCI”
034 Sauerstoff).
CAUTION
During operation the surface of the machine may reach temperatures of more than 70°C.
Risk of burns!
●
Avoid contact with the machine during and directly after operation.
CAUTION
Noise of running machine.
Risk of damage to hearing!
If persons are present in the vicinity of a non noise insulated machine over extended periods:
●
Make sure that ear protection is being used.
NOTICE
The machine can be shipped without oil.
Operation without oil will ruin the machine in short time!
●
Prior to commissioning, the machine must be filled with oil, see
NOTICE
The machine can be shipped without cooling liquid.
Operation without cooling liquid will ruin the machine in short time!
●
Prior to commissioning, the machine must be filled with cooling liquid, see Filling Cooling Liquid.