Installation | 5
0870573045_NC1500B_VR_A0002_IM_en
11 / 32
5.2.2 Discharge Connection
Connection size:
At the machine discharge connection:
– DN80 PN16, EN 1092-1
– ANSI 150, 3” (optional)
• Make sure that the discharged gas will flow without obstruction. Do not shut off or
throttle the discharge line or use it as a pressurised air source.
• Make sure that the counter pressure (also termed back pressure) at the discharge con-
nection (OUT) does not exceed the maximum allowable discharge pressure, see
5.2.3 Cooling Liquid Connection
CLI
CLO
INJ
CLI
Cooling liquid inlet connection
CLO
Cooling liquid outlet connection
INJ
Injection point
Connection size:
– G1/2, ISO 228-1 (CLI / CLO)
– G1/2, ISO 228-1 (INJ)
5.3 Earth Connection
In order to prevent the machine from creating an electrostatic charge:
• Connect the earth connection of the machine (ECP)
Earth connection of
the machine (ECP)