Technical Data | 12
0870203597_NC0100-0300B_WCV_Ex_-0001_IM_en
55 / 60
12 Technical Data
NC 0100 B
NC 0200 B
NC 0300 B
Pumping speed
(50Hz / 60Hz)
m³/h
110 / 130
220 / 265
320 / 385
Ultimate pressure
with standard coating “NC xxxx xxx”
(50Hz / 60Hz)
hPa (mbar)
abs.
≤
0.05 /
≤
0.01
Ultimate pressure
with special coating NT xxxx xxx”
(50Hz / 60Hz)
hPa (mbar)
abs.
≤
0.5 /
≤
0.1
Nominal motor rating
(50Hz / 60Hz)
kW
3.5 / 4.8
6 / 7.6
7.5 / 9.5
Nominal motor speed
(50Hz / 60Hz)
min
-1
3000 / 3600
Nominal motor torque
Nm
≤
12
≤
25
≤
50
Starting motor torque
Nm
≤
46
≤
90
≤
115
Noise level (EN ISO 2151)
(50Hz / 60Hz)
dB(A)
≤
70 /
≤
74
≤
71 /
≤
76
≤
72 /
≤
77
Ambient temperature range
°C
-20 … 40
Max. allowable counter pressure at the dis-
charge
hPa (mbar)
300
Max. allowable gas inlet temperature
°C
60
Relative humidity
at 30 °C
90%
Ambient pressure
Atmospheric pressure
Cooling water requirements
Oil capacity - motor side
l
1.1
Oil capacity - suction side
l
0.45
Cooling liquid capacity approx.
(with plate heat exchanger only)
l
4
5.5
6.5
Weight approx.
kg
300
350
400
13 Cooling Liquid
Zitrec M-25 (ready-to-use)
Part number 5 L packaging
0831 563 469
Part number 25 L packaging
0831 563 468
The cooling liquid Zitrec M-25 is ready-to-use and does not require additional water.
For further information, consult the website
.
14 Oil
VE 101
ISO-VG
100
Part number 1 L packaging
0831 000 099
Part number 5 L packaging
0831 000 100