background image

Operation

Product manual 2TMD041800D0008

35

9.4.2 

Releasing the lock with a password set on the local outdoor station

Precondition

On the home screen of the outdoor station, tap "

 ", followed by [#] [*] [engineering

password] [#] to access the "Settings" screen.

On the "Settings" screen, complete the following settings:

"Access control">>"Password">>"Public password">>"On">>enter a 3~8 digits password.

Password rule

This password must not include continuously increasing or decreasing numbers
(e.g. 123456, 654321). Three consecutive identical numbers are similarly not
permitted (e.g. 123444, 666888).

Releasing the lock by entering the password

On the home screen of the outdoor station, tap "

 ", enter [#] [password] [#], followed by

"

 " to release the lock.

Wrong password

If an incorrect password is entered 10 times within 5 minutes, no further
attempts are permitted for the next 5 minutes.

Содержание Busch-Welcome H8138.T 03 Series

Страница 1: ...2TMD041800D0008 27 10 2022 Product manual Busch Welcome IP H8138 T 03 IP touch 5 outdoor station ...

Страница 2: ...mantling 19 8 Commissioning 20 8 1 Welcome screen and home screen 20 8 2 Entering the Settings screen 21 8 3 Engineering settings 22 8 4 Access control settings 23 8 5 System settings 24 9 Operation 27 9 1 Call a resident via keypad 27 9 2 Call a resident via the address book 30 9 3 Call guard unit 32 9 4 Releasing the lock by entering a password 33 9 4 1 Releasing the lock with a password set on ...

Страница 3: ...ntents Product manual 2TMD041800D0008 3 10 2 Performance and service 42 10 3 Deployment guideline 43 10 4 Upgrading 43 10 5 Backup Restore 43 10 6 Malware prevention solution 43 10 7 Password rule 43 11 Notice 44 ...

Страница 4: ...his manual in a safe place If you pass the device on also pass on this manual along with it Busch Jaeger accepts no liability for any failure to observe the instructions in this manual 2 Safety Warning Electric voltage Dangerous currents flow through the body when coming into direct or indirect contact with live components This can result in electric shock burns or even death Disconnect the mains ...

Страница 5: ...station runs in Security mode by default to guarantee high security In Security mode this outdoor station requires a certificate issued by the management software before it can function normally Video privacy Making and saving video recordings can infringe on personal rights Always observe the applicable legal and labeling requirements for the placement and operation of video components ...

Страница 6: ...eger devices All packaging materials and devices from Busch Jaeger bear the markings and test seals for proper disposal Always dispose of the packing materials and electric devices and their components via an authorized collection facility or disposal company Busch Jaeger products meet the legal requirements in particular the laws governing electronic and electrical devices and the REACH ordinance...

Страница 7: ...uct description 5 1 Device type Article number Product ID Product name Colour Size HxWxD Unit mm H81381T S 03 2TMA130010X0027 IP touch 5 outdoor station Stainless steel 135 x 349 x 29 H81381T W 03 2TMA130010W0017 IP touch 5 outdoor station White 135 x 349 x 29 ...

Страница 8: ...Product description Product manual 2TMD041800D0008 8 5 2 Control elements No Function 1 Camera 2 Speaker and microphone integration 3 5 inch touch display 4 End strip ...

Страница 9: ...y 4 Plug in clamps LOCK GND for door opener 5 Plug in clamps COM NC NO for floating output door opener 6 LAN PoE 7 Connector for next module 8 Connector for exit button 9 Connector for the sensor used for door status detection 10 Connector for 5 display module 11 Connector for previous module 12 Connector for A V module 13 Connector for Wiegand output It supports 26 bits and 34 bits ...

Страница 10: ...ke lock 12V Power on to open 12 V Type A B Electrical strike lock 24V Power on to open 24 V Type B Electrical rim lock 12 V Power on to open 12 V Type A B Electrical mortise lock Power off to open 12 V Type C Magnetic lock Power off to open 12 24 V Type C GND NO DC NC LOCK COM GND NO DC NC LOCK COM GND NO DC NC LOCK COM PS PS Type A Type B Type C ...

Страница 11: ...ent 27 V 410 mA 24 V 450 mA Operating temperature 20 C 55 C Camera type CMOS Camera viewing angle 130 Resolution ratio HD 1280 x 720 pixel Ambient brightness 50000 Lux Power supply for door opener 18 V 4 A impulse max 250 mA holding Floating output for door opener 230 V 3 A 30 V 3 A Video codec H 264 Audio codec G 711 IP level IP 54 IK level IK 07 ...

Страница 12: ...edge and experience Incorrect installation endangers your life and that of the user of the electrical system Incorrect installation can cause serious damage to property e g due to fire The minimum necessary expert knowledge and requirements for the installation are as follows Apply the five safety rules DIN VDE 0105 EN 50110 1 Disconnect 2 Secure against being re connected 3 Ensure there is no vol...

Страница 13: ...Mounting Installation Product manual 2TMD041800D0008 13 7 2 Mounting 7 2 1 Preparation Use gloves to protect yourself against cuts 7 2 2 Installation height 1 5 m 5 feet ...

Страница 14: ...041800D0008 14 Note The following installation situations must be avoided without fail to ensure picture quality Direct light Direct sunlight Extremely bright picture background Highly reflective walls on the opposite side of the door station ...

Страница 15: ...Mounting Installation Product manual 2TMD041800D0008 15 7 2 3 Surface mounted installation 2 83 mm 40 mm 71 mm 1X4 3 4 5 6 7 8 2 1 ...

Страница 16: ...Mounting Installation Product manual 2TMD041800D0008 16 7 2 4 Flush mounted installation 1 Flush mounted without pre installation box 117 mm 46 mm 336 mm 1X4 2 1 4 5 6 7 8 9 3 ...

Страница 17: ...Mounting Installation Product manual 2TMD041800D0008 17 2 Flush mounted with pre installation box 5 6 7 8 9 10 4 34 6 mm 68 m m 126 m m 1X4 3 2 1 ...

Страница 18: ...Mounting Installation Product manual 2TMD041800D0008 18 7 2 5 Cavity wall installation 1 2 3 5 6 7 8 6 4 5 10 9 ...

Страница 19: ...Mounting Installation Product manual 2TMD041800D0008 19 7 2 6 Dismantling ...

Страница 20: ...low on the right No Function 1 Welcome message If there is no bulletin the Welcome screen will display according to the welcome screen time 1 60 s 2 Developer information Developer information can be text or a picture It is sent from the management software 3 Bulletin If there are any bulletins the screen will be displayed according to the number of bulletins before accessing the home screen Bulle...

Страница 21: ...ing password must be changed the first time you access the engineering settings The system default is 345678 This password should only be used for initial setting work and should be changed to another password It cannot be used as the actual password Note If an incorrect engineering password is entered 10 times within 5 minutes no further attempts are permitted for the next 5 minutes ...

Страница 22: ...tation 001 999 Device type Outdoor station Gate station Device no Outdoor station 01 64 Gate station 01 32 System attribute Call guard unit On 01 32 Off default Digits of indoor station 3 digits 4 digits Block digits Gate station 1 digit 2 digits 3 digits Default call type Call from address book Call via keypad Call mode Physical address Logical address Compatible mode On Off Default Change passwo...

Страница 23: ...blic password On 3 8 digits Off default Card mode Safe mode On default Off User card Enrol Outdoor station Maximum 5 000 pcs Gate station Maximum 40 000 pcs Delete card Delete all Card setting Copy card to another outdoor station gate station Address of outdoor station gate station Unlock type when swiping Default lock Subsidiary lock Unlock manually Contact Add Outdoor station Maximum 1 200 Gate ...

Страница 24: ... Off Auto brightness On default Off 1 10 2 Contacts font size 1 4 Data and time Time sync from On sync time from management software Off Local setting Set time hh mm Set date dd mm yyyy Time format 12 hours 24 hours default Date format DD MM YYYY default MM DD YYYY YYYY MM DD Unlock time Lock GND 1 10 s NO NC COM 1 10 s 1 Voice prompt If this function is enabled the outdoor station will play the s...

Страница 25: ...ttings Welcome screen time 1 60 s Developer information On default Off Bulletin On default Off Lift settings Block no 001 999 Lift control On current floor 7 63 Off default Language Other Wiegand output Off default 26 bits 34 bits Anti flicker 60 Hz default 50 Hz Door open alarm On can be set as Local alarm Off default Temper alarm On Off default Forward to guard unit On Off default 1 Display Resi...

Страница 26: ...n System settings Help Version Major version MCU version Hardware version Display version Serial number This number is used to obtain the certificate issued by the management software Signature Displays the value if the certificate issued is obtained successfully QR code Manual ...

Страница 27: ...ed by engineering password to access the Settings screen On the Settings screen complete the following settings Engineering settings System attribute Default call type Call via keypad Engineering settings System attribute Call mode Physical address Initiating a call using the room number On the home screen enter the room number e g 0101 followed by to initiate a call ...

Страница 28: ... settings System attribute Default call type Call via keypad Engineering settings System attribute Call mode Logical address Access control Contact Add number Specific code Name see the picture below If device type outdoor station number room number If device type gate station number building number room number Note It is recommended that contacts are created and maintained only using the local ou...

Страница 29: ...Operation Product manual 2TMD041800D0008 29 Initiating a call using the specific code On the home screen enter the specific code e g A1 followed by to initiate a call ...

Страница 30: ...ollowing settings Engineering settings System attribute Default call type Call from address book Access control Contact Add number Specific code Name see the picture below If device type outdoor station number room number If device type gate station number building number room number Note It is recommended that contacts are created and maintained only using the local outdoor station or only using ...

Страница 31: ...iating a call from the address book On the home screen tap a contact from the address book to access a countdown screen Tap Stop call to pause the call Tap the countdown number or call button to continue the call Tap other position to cancel the call ...

Страница 32: ...reen tap followed by engineering password to access the Settings screen On the Settings screen complete the following settings Engineering settings System attribute Call guard unit On enter the guard unit number 1 32 Call guard unit On the home screen click Call guard unit to initiate a call ...

Страница 33: ...ccess the Settings screen On the Settings screen complete the following settings Access control Password Private password On On the System settings screen of the indoor station follow the steps below Change password Change unlock password Set a 3 8 digits password Password rule This password must not include continuously increasing or decreasing numbers e g 123456 654321 Three consecutive identica...

Страница 34: ...wed by to release the lock If call mode physical and device type outdoor station address room number If call mode physical and device type gate station address building number room number If call mode logical address specific code Wrong password If an incorrect password is entered 10 times within 5 minutes no further attempts are permitted for the next 5 minutes ...

Страница 35: ...sword Public password On enter a 3 8 digits password Password rule This password must not include continuously increasing or decreasing numbers e g 123456 654321 Three consecutive identical numbers are similarly not permitted e g 123444 666888 Releasing the lock by entering the password On the home screen of the outdoor station tap enter password followed by to release the lock Wrong password If a...

Страница 36: ...an unlock password on the Welcome App For more information please see the Welcome App manual Releasing the lock by entering a password On the screen enter the password followed by to release the lock Wrong password If an incorrect password is entered 10 times within 5 minutes no further attempts are permitted for the next 5 minutes ...

Страница 37: ...e an unlock password in the management software For more details please see the management software manual Releasing the lock by entering a password On the screen enter the password followed by to release the lock Wrong password If an incorrect password is entered 10 times within 5 minutes no further attempts are permitted for the next 5 minutes ...

Страница 38: ...00D0008 38 9 5 Releasing the lock with a QR code set on the App You need to pair the Welcome App with an indoor station before this function is used 1 Create an unlock QR code Please see the Welcome App product manual for more details ...

Страница 39: ...e Settings screen 2 On the Settings screen tap System settings Unlock type configuration QR code unlock On to enable the QR code function 3 Go back to the home screen tap a QR code icon will be displayed in the lower left corner on the screen 4 Tap the QR code icon on the outdoor station then place the QR code on your mobile in front of the camera on the outdoor station to release the lock ...

Страница 40: ...ll only support IC cards with a token Access control User card Enrol Swipe the IC cards on the specified area see the diagram below to register them Access control Card setting Unlock type when swiping Select a lock type e g Default lock or Subsidiary lock if Unlock manually is selected you can select a lock type to release on a pop up window each time when you swipe the IC card on the specified a...

Страница 41: ...he lock by swiping an IC card Swipe a registered IC card on the specified area to release the lock IC card specification Operating frequency 13 56 MHz Standard ISO 14443A Support card Mifare one S50 S70 Mifare desfire EV1 EV2 Output format Wiegand 26 34 bit ...

Страница 42: ...r losses related to such security breaches unauthorized access interference intrusion leakage and or theft of data or information Although Busch Jaeger provides functionality testing on the products and updates that we release you should institute your own testing program for any product updates or other major system updates to include but not limited to code changes configuration file changes thi...

Страница 43: ...ice This will prevent sensitive data leaks It is recommended to apply MAC filter and Rate limiter in the switch to prevent DOS attacks 10 4 Upgrading Device supports firmware updates via management software a signature file will be used to verify the authentication and integrity of firmware 10 5 Backup Restore None 10 6 Malware prevention solution The H8138 T device is not susceptible to malware b...

Страница 44: ...ications agreed to at the time of ordering apply to all orders Busch Jaeger accepts no responsibility for possible errors or incompleteness in this document We reserve all rights to this document and the topics and illustrations contained therein The document and its contents or excerpts thereof must not be reproduced transmitted or reused by third parties without prior written consent by Busch Ja...

Страница 45: ... of the ABB Group Freisenbergstraße 2 58513 Lüdenscheid www BUSCH JAEGER de info bje de abb com Central sales service Tel 49 2351 956 1600 Fax 49 2351 956 1700 Copyright 2021 Busch Jaeger Elektro GmbH All rights reserved 2TMD041800D0008 ...

Отзывы: