![Busch-Jaeger Busch-Timer 6455 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/busch-jaeger/busch-timer-6455/busch-timer-6455_operating-instructions-manual_2833744023.webp)
Operating Instructions
Busch-Timer
®
Operation
Operating Instructions | 1473-1-8164
— 23 —
Pos: 80 /#Neustr uktur#/Online-Dokumentati on (+KN X)/Überschriften (--> Für all e D okumente <--)/3. Ebene/P - R /Rückfahri mpuls @ 28\mod_1347002347378_15.docx @ 231978 @ 22222 @ 1
5.9.2
Return pulse
Pos: 81 /#Neustruktur#/Online-Dokumentation (+KNX)/Bedienung/Timer/Einstellungen - Sonderfunktionen - Rückfahrimpuls - 6455 Jalousie @ 26\mod_1343815961406_15.docx @ 226444 @ 2 @ 1
With function "Return pulse" you can let the blind move up from the bottom end position until the ventilation slots
are open. With this function the blind is, after closing (DOWN command), moved in the UP direction for the set
time.
The adjustment range lies between 0 and 255.
Setting
Meaning
0
No return pulse
255
Maximum duration, corresponds to around 30 seconds
The return pulse is executed only if the blind was started previously from the top end position.
The return pulses can be entered separately for the following functions:
•
Switching times
•
Additional switching times (if active)
•
Twilight function (only with sensor)
Fig. 16: Menu item – Return pulse