113
of 175
Slot
Index Description
Value
Meaning of value
Type
Len R/W
77
11
Switchpoint S1
channel
Note:
At the end, entry
must be adopted
through index 14.
0
1
2
Channel X
Channel Y1
Channel Y2
U16
2
RW
77
12
Switchpoint S1
level
Note:
At the end, entry
must be adopted
through index 14.
0
1
Low active
High active
U16
2
RW
77
13
Switchpoint 1
reference
Note:
At the end, entry
must be adopted
through index 14.
0
1
Absolute reference
Trigger reference
U16
2
RW
77
14
Switchpoint 1
Copy settings
Note:
Values entered
into indices 10 - 13 are
adopted.
EVENT
Writing an arbitrary byte
initiates action
U8
1
WO
7.4.41 Realtime switchpoints S2 (Slot 78)
Slot
Index Description
Value
Meaning of value
Type
Len R/W
78
0
Not possible
-
-
X
78
1 .. 9 Reserved
-
-
X
78
10..
See slot 77
7.4.42 Realtime switchpoints S3 (Slot 79)
Slot
Index Description
Value
Meaning of value
Type
Len R/W
79
0
Not possible
-
-
X
79
1 .. 9 Reserved
-
-
X
79
10..
See slot 77