The following terms are used throughout this manual to bring attention to the presence of hazards of various risk levels.

Basic Operation

A.

  General

1.  This manual covers the proper care and use of the 

Alpine™ (ALP) Condensing High Efficiency Gas 

Fired Boiler

2.  Instructions to safely light and shut down this boiler 

are shown on page 4, as well as on a label affixed to 

the boiler.  Control locations shown in Figure 1.

3. 

The Alpine™ (ALP) boilers

 use an electronic 

means built into the ignition system to extinguish 

the burner in the event that flames exit the 

combustion chamber. If the boiler fails to fire, call 

a qualified heating service agency to diagnose and 

correct the problem.

4. 

Alpine™ (ALP) boilers – 

These boilers are 

equipped with a safety feature which will shut down 

the burner in the event that there is a blockage in 

the vent system. In the event that the boiler fails to 

function, and the boiler is vented through an outside 
wall accessible from the ground, inspect the vent 
terminal on the outside wall for a blockage such 
as a bee’s nest or ice. If a blockage is found, the 

burner should ignite approximately 30 seconds after 

the blockage is removed. If no blockage is found, 
or if the terminal is inaccessible from the ground, 

the problem must be diagnosed and corrected by a 

qualified gas service technician. 

DANGER

There are no user serviceable parts on this boiler.  Attempts to service this boiler by someone other  than a 

qualified gas service technician could void the warranty, cause property damage, personal injury or loss of 

life.

CAUTION

Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical 

supply to the pump. Instead, shut off the gas supply at a location external to the appliance.

En cas de surchauffe ou si I'admission de gaz ne peut étre coupée, ne pas couper ni débrancher 

l'alimentation électrique de la pompe.  Fermer plutôt le robinet d'admission de gaz à l'extérieur de I'appareil.
Do not use this boiler if any part has been under water. Immediately call a qualified service technician to 

inspect the boiler and to replace any part of the control system and any gas control which has been under 

water.

CAUTION

Like all central heating appliances, this boiler is equipped with safety devices, which could cause it to 

shutdown, requiring service to restore normal operation. Where such a shutdown could result in damage 

from low temperatures (such as frozen pipes), do not leave the heating system unattended during cold 

weather unless alarms or other safeguards are in place to prevent damage.  

WARNING

Indicates a potentially hazardous situation which, 

if not avoided, could result in death, serious injury 

or substantial property damage.

CAUTION

Indicates a potentially hazardous situation which, 

if  not  avoided,  may  result  in  moderate  or  minor 

injury or property damage.

Содержание Alpine Series

Страница 1: ...nd service must be performed by a qualified installer service agency or the gas supplier AVERTISSEMENT Assurez vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d incendie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflam mables dans le voisinage...

Страница 2: ...DANGER There are no user serviceable parts on this boiler Attempts to service this boiler by someone other than a qualified gas service technician could void the warranty cause property damage personal injury or loss of life CAUTION Should overheating occur or the gas supply fail to shut off do not turn off or disconnect the electrical supply to the pump Instead shut off the gas supply at a locati...

Страница 3: ...ts Heating system water Leaks Carbon soot in or near the burner compartment area Make sure that the condensate drain system is unobstructed and leak tight CAUTION The Alpine ALP has a heat exchanger made from a special stainless steel alloy which can be severely damaged by frequent additions of water or by the addition of boiler water additives which are not designed for use with stainless steel b...

Страница 4: ... Figure 1 Control Locations shown with optional concentric vent collar ...

Страница 5: ... Figure 2 Lighting Instructions Alpine Series Lighting and Operating Instructions ...

Страница 6: ...t 5 All Concentric internal Vent pipe joints must be secure gas tight and watertight 6 Condensate drain must be free of obstruction and allow condensate to flow freely If corrective action is required contact your installer or qualified service agency C Inspect burner Flames Monthly 1 Remove lower front door assembly 2 Adjust thermostat to the highest setting to initiate boiler firing 3 View burne...

Страница 7: ...o the normal setting to stop boiler firing D Schedule Inspection by Your Installer or Qualified Service Agency Annually or at Beginning of Heating Season For continued safe operation either your installer or a qualified service agency must provide a more detailed inspection of burner heat exchanger controls and vent system and provide maintenance as specified in Installation Operating and Service ...

Страница 8: ...y service or repair work involving RCF without wearing the following protective gear 1 A National Institute for Occupational Safety and Health NIOSH approved respirator 2 Long sleeved loose fitting clothing 3 Gloves 4 Eye Protection Take steps to assure adequate ventilation Wash all exposed body areas gently with soap and water after contact Wash work clothes separately from other laundry and rins...

Отзывы: