oPerAtIng the DevIce
18
Operating the Device
►
Before switching the integrated amplifier on, check all cable connections for correct
polarity (POS, NEG) . After initial or re-wiring, we recommend slowly increasing the
volume until you are certain that everything is connected correctly .
Power on/off
The device is equipped with two control elements for power on/off:
• The power switch (15) is located on the back side of the device . Actuating the power
switch connects/disconnects the standby transformer to/from the power supply .
• The power on/off switch (8) is located on the front side of the device . Actuating the
power on/off switch switches the device between standby mode, operating mode,
and OFF .
►
Before switching the integrated amplifier on, turn down the volume; do not increase
the volume until after you have switched the device on .
Switching the device to standby mode when it is off:
1 .
Set the mains switch on the back side of the device to
on
.
The standby transformer is connected to the power supply .
2 .
Set the power on/off switch (8) on the front side into the center position,
stby
.
The device switches into standby mode and the operation LED (9) lights up in
orange .
Switching the device on from standby mode:
►
Briefly push the power on/off switch (8) upward into the
on
position or press the
POWER (24) button on the remote control .
The device switches into standby mode and the operation LED (9) lights up in
red .
After switching the device on, the monitoring electronics take a few seconds to
perform a complete check of the integrated amplifier . If no errors are present, the
speaker outputs are then enabled .
note:
The
pre-out only
mode is an exception . In this mode, the 101 is switched on, but the
power amp is not . For more information, please see „Pre-out only mode“ on page 21 .
Switching the device from operation into standby mode:
►
Briefly push the power on/off switch (8) upward into the
on
position or press the
POWER (24) button on the remote control .
The device switches into standby mode and the operation LED (9) lights up in
orange .
The power switch (15) can remain in the
on
position . Thus, you can conveniently
control the device using the power on/off switch (8), or the remote control . As only the
standby transformer is active during standby mode, minimum electricity is consumed .
Switching off the device with the power on/off switch:
►
Move the power on/off switch (8) downward into the
off
position .
The device is switched off and cannot be switched back on with the remote
control . The operation LED (9) goes out .