background image

 

 

10

 

!

 

 

Lightening strikes

 

During  the  summer  months,  malfunctions  often  occur  due  to  voltage  spikes  in  the  power 
lines after lightning strikes. Completely unplugging the power cord offers the only effective 
protection. Merely switching the unit off does not suffice since voltage spikes are able to arc 
over separated contacts. 

 
 

Fuses

 

The fuses are located inside the unit and should only be changed by a qualified technician. 

 
 

Warranty 

We  offer  a  warranty  of  3  years  for  this  unit.  It  is  a  precondition  that  the  unit  has  been 
hooked-up and operated correctly and is mechanically undamaged. 
Opening the unit, modifying it or dismantling outlets will void the warranty instantly. 

 
 

Care

 

Never clean the housing with a wet cloth or chemical cleaning agent. Always make sure that 
no liquid gets into the housing. 

 
 

 
 
 

This symbol on the equipment points to important notes, which can be found in the owner´ 

 

s manual. 

 
 

 

 
 
 
 

This symbol on or inside the equipment warns of dangerously high voltage. 

 
 

 
 
 

 
 
 
 

If  the  unit  is  to  be  put  out  of  operation  definitively,  take  it  to  a  local  recycling  plant  for  a 

 

disposal, which is not harmful to the environment. 

 
 
 
 

 
 
 

CAUTION:

 

The  unit  must  only  be  opened  by  qualified  experts.  Opening  the  unit  provides  the 
chance  of  encountering  dangerously  high  voltage.  Therefore  the  power  cord  must 
always be unplugged before opening the equipment. 

 

Содержание 909 MK5

Страница 1: ...FERENCE LINE POWER AMP 909 MK5 HIGH END MADE IN GERMANY BURMESTER AUDIOSYSTEME GMBH WILHELM KABUS STRA E 47 10829 BERLIN GERMANY FON 49 0 30 78 79 68 0 FAX 49 0 30 78 79 68 68 E MAIL mail burmester de...

Страница 2: ...VERSION 1 2 FROM March 24 th 2011...

Страница 3: ...ting flexibility We recommend reading this user manual at least once in its entirety before initial operation This will enable you to make full use of all capabilities of this outstanding audiophile i...

Страница 4: ...ING and SET UP POSITION 1 VIEWS OF UNIT 2 3 CONNECTING 4 OPERATING CONTROLS 5 PROTECTIVE CIRCUITS 5 WIRING DIAGRAMS 6 8 STEREO operation 6 MONO operation 7 BI AMPING operation 8 GENERAL INSTRUCTIONS 9...

Страница 5: ...ping the original packaging material in case of a move or future shipping Setting up Too low or too high temperatures may cause damage inside of the power amp Therefore we recommend you leave the unit...

Страница 6: ...2 VIEWS OF UNIT FRONT VIEW 1 STAND BY LED 3 POWER LED 2 POWER button 4 ERROR display...

Страница 7: ...TE output 12 Loudspeaker output left channel negative 7 Loudspeaker output right channel positive 13 Loudspeaker output left channel positive 8 Loudspeaker output right channel negative 14 REMOTE inpu...

Страница 8: ...en their sonic excellence and functional convenience a thousand times over Speaker cables can be connected via pure copper spade plugs or via banana plugs We recommend using pure copper spade plugs CA...

Страница 9: ...tection switches off the output relays and the POWER LED 3 goes out The unit is switched into stand by mode and the ERROR display 4 shows a 1 As a precaution we recommend to lower the volume and wait...

Страница 10: ...stereo signal To use the 909 in STEREO mode make the following connections 5 input right channel 7 positive loudspeaker binding post right channel 8 negative loudspeaker binding post right channel 15...

Страница 11: ...h is available on request at your local dealer To use the 909 in MONO mode make the following connections 5 MONO adapter red side 7 positive loudspeaker binding post 8 not connected 15 MONO adapter bl...

Страница 12: ...local dealer To use the 909 in BI AMPING mode make the following connections 5 BI AMPING adapter red side 7 positive loudspeaker binding post high mid 8 negative loudspeaker binding post high mid 15...

Страница 13: ...e by an expert only For AC connection please use only the three pronged power cable provided The grounding pin should not be bypassed under any circumstances Connect the component only to a wall outle...

Страница 14: ...nically undamaged Opening the unit modifying it or dismantling outlets will void the warranty instantly Care Never clean the housing with a wet cloth or chemical cleaning agent Always make sure that n...

Страница 15: ...slow 16A E for 100V 127V 50 60Hz F1 F3 slow 3 15A E 1F2 F4 slow 2 0A E Unit fuse 2x slow 16A E Power consumption max 1 500W idling 60W stand by 4W Output power at 4Ohm 2 x 600W 1x 1930W at 1Ohm 2 x 12...