Connection bolt of the amplifier with a screwed-on loop half
The loop elements possess different contact surfaces on each side. On the back a square for installation
of the connecting bolts, in the front a round for contact with the washer. The sides must not be confused,
otherwise the proper function can not be guaranteed.
Installing a loop half to the assembly cubes (2nd screw is still missing)
The threaded rod has a normal nut at its lower end. To counter against the middle bolt of the amplifier, a
suitable open-end wrench is required. Hold the bolt with a second wrench! It is important to ensure that the
mounting cubes are at a 45° angle with their surfaces to the amplifier housing.
The loop elements also have a large contact surface at the top connection and round contact surfaces at
the front. To ensure good contact, the element must rest on the mounting cube with the right side.
Caution!
It is absolutely necessary to avoid twisting the bolts on the amplifier! If the flat surfaces of the
connecting bolts deviate significantly from the 45° direction to the housing, then a careful turning to the
correct position with the aid of an open-end wrench can be attempted. If this requires a great deal of effort,
or if the bolt loosens, the amplifier must be dismantled and the internal screwed connections must be re-
fastened.
EDITION
DATE
NAME
K & M Burkhard Reuter
Page
9
of
9
1.5
8/19/19
B. Reuter
RLA4