Auxiliary functions
Type 8792, 8793 REV.2
For simulation of process and process valve:
→
/ Select
CONTROL.sim
.
For description see chapter “16.1.23.2. CONTROL.sim – Simulation of the process and process valve”.
Leaving the
SIMULATION
menu:
→
Select
EXIT
. Return to the main menu (MAIN).
→
Select
EXIT
. Switching from setting level
process level.
You have activated and parameterized the set-point value simulation.
16.1.23.2.
CONTROL.sim
– Simulation of the process and process valve
The settings to simulate the process and the process valve are made in the
CONTROL.sim
menu.
Settings
Type of simulation:
x.SIM
Simulation of the process valve.
p.SIM
Simulation of the process.
Parameterization of
the process:
SIM.Gain
Specify amplification factor.
SIM.Delay
Specify time constant in seconds.
Example of a simulated process:
63%
1
SIM.Gain
(Amplification factor [Kp])
t
SIM.Delay
(Time constant [T] in s)
Effect of parameterization on the behavior of the PT1 element
Output of the simulated
process
Input of the simulated
process
y
u
5
Figure 40:
Example of a simulated process. Behavior of the PT1 element