OPERATING INSTRUCTIONS

The operating instructions contain important information.

 

Read the operating instructions carefully and follow the safety 

instructions in particular, and also observe the operating conditions.

 

Operating instructions must be available to each user.

 

The liability and warranty for the device are void if the operating 

instructions are not followed.

1.1 

Symbols

 

Designates an instruction to prevent risks.

 

designates a procedure which you must carry out.

Warning of injuries:

DANGER!

Imminent danger! Serious or fatal injuries.

WARNING!

Potential danger! Serious or fatal injuries.

CAUTION!

Danger! Minor or moderately severe injuries.

Warns of damage to property:

NOTE! 

INTENDED USE

Incorrect use of the solenoid valve Type 0255 / 0355 can be dan-

gerous to people, nearby equipment and the environment.

 

The device is designed to control, shut off and meter neutral 

media up to a viscosity of 21 mm

2

/s.

 

Provided the cable plug is connected and installed correctly, e.g. 

Bürkert Type 2508, the device satisfies protection class IP65 in 

accordance with DIN EN 60529 / IEC 60529.

 

Use according to the permitted data, operating conditions and 

conditions of use specified in the contract documents and oper-

ating instructions.

 

Correct transportation, correct storage and installation and care-

ful use and maintenance are essential for reliable and problem-

free operation.

 

Use the device only as intended.

2.1 

Definition of term

In these operating instructions, the term “device” always refers to 

the solenoid valve Type 0255 and 0355. 

english

Содержание 0255

Страница 1: ...Bedienungsanleitung Manuel d utilisation Operating Instructions Type 0255 0355 2 2 and 3 2 way solenoid valve 2 2 und 3 2 Wege Magnetventil Électrovanne 2 2 et 3 2 voies ...

Страница 2: ... property NOTE 2 INTENDED USE Incorrect use of the solenoid valve Type 0255 0355 can be dan gerous to people nearby equipment and the environment The device is designed to control shut off and meter neutral media up to a viscosity of 21 mm2 s Provided the cable plug is connected and installed correctly e g Bürkert Type 2508 the device satisfies protection class IP65 in accordance with DIN EN 60529...

Страница 3: ... or pneumatic supply ensure that the process is restarted in a defined or controlled manner Do not put any loads on the body The general rules of technology apply to application planning and operation of the device 3 BASIC SAFETY INSTRUCTIONS These safety instructions do not make allowance for any contingencies and events which may arise during installation operation and maintenance Danger high pr...

Страница 4: ...Type 0255 0355 4 TECHNICAL DATA 4 1 Operating conditions The following values are indicated on the type label Voltage Tolerance 10 Current type Coil power consumption active power in W at operating temperature Pressure range Body material Brass MS Stainless steel VA Sealing material FKM EPDM NBR PTFE Steel Circuit function Type 0255 A A P 2 2 way valve closed in rest position Circuit function Type...

Страница 5: ...on Important information for functional reliability during con tinuous operation If standstill for a long period at least 1 2 activations per day are recommended Service life High switching frequency and high pres sures reduce the service life 4 2 1 Permitted temperature Permitted temperature depending on coil material and sealing material Coil material Sealing material Medium temperature Epoxy Me...

Страница 6: ...raulic substances 4 for special design only 4 3 Conformity In accordance with the EU Declaration of conformity Type 0255 0355 is compliant with the EU Directives 4 4 Standards The applied standards which verify conformity with the EU Direc tives can be found on the EU Type Examination Certificate and or the EU Declaration of Conformity 4 5 Type label Type Circuit function Orifice Sealing material ...

Страница 7: ...thorized technicians only and with the appropriate tools Risk of injury from unintentional activation of the system and an uncontrolled restart Secure system from unintentional activation Following assembly ensure a controlled restart 5 2 Before installation Installation position any actuator preferably upwards Procedure Check pipelines for dirt and clean Install a dirt filter before the valve inl...

Страница 8: ...nnected there is a risk of electric shock Always connect protective conductor and check electrical continuity Note the voltage and current type as specified on the label Procedure Tighten cable plug for permitted types see data sheet observing max torque 1 Nm Check that seal is fitted correctly Connect protective conductor and check electrical continuity Seal ensure position is correct max 1 Nm Au...

Страница 9: ...voltage and pressure have been switched on the pipelines are clean adequately high power supply is applied Malfunction Possible cause Valve does not switch Short circuit or coil interrupted Inadequate power supply Core core area is dirty Medium pressure outside the permitted pressure range Valve does not close Internal space of the valve is dirty 7 SPARE PARTS CAUTION Risk of injury and or damage ...

Страница 10: ...t in shock resistant packaging Avoid exceeding or dropping below the allowable storage temperature Incorrect storage may damage the device Store the device in a dry and dust free location Storage temperature 40 80 C Damage to the environment caused by device components contaminated with media Dispose of the device and packaging in an environmentally friendly manner Observe applicable regulations o...

Страница 11: ...nternet www buerkert de Manuel d utilisation et fiches techniques sur Internet www buerkert fr Bürkert Werke GmbH Co KG 2014 2017 Operating Instructions 1711 05_EU ML_00893044 Original DE Bürkert Fluid Control Systems Sales Center Christian Bürkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 10 91 111 Fax 49 0 7940 10 91 448 E mail info de buerkert com ...

Отзывы: