Burkert PTB 01 ATEX 2175 Скачать руководство пользователя страница 6

6

Basic safety instructions

Basic safety instructiOns

These safety instructions do not consider any contingencies 

or incidents which occur during installation, operation and 

maintenance.
The operator is responsible for observing the location-specific 

safety regulations, also with reference to the personnel.

danger – high pressure.

When reaching into the system, there is an acute risk of injury.

 

Before working on the device or system, switch off the pres-

sure. Vent or drain lines.

 

During the installation, make certain the flow direction is 

correct.

 

Observe applicable accident prevention and safety regula-

tions for pressurized devices.

risk of injury from electric shock.

 

Before working on the device or system, switch off the 

power supply. Secure against reactivation.

 

Observe applicable accident prevention and safety regula-

tions for electrical equipment.

Risk of burns or fire from hot device surface due to pro-

longed duty cycle.

The solenoid coil can get very hot during long-term operation.

 

Do not touch the device unless wearing protective gloves.

 

Keep the device away from highly flammable substances 

and media.

risk of explosion.

 

The device is a closed system and must not be modified in 

any way.

A device which has already been used in a non-hazardous “i” 

circuit must no longer be used in the hazardous “i” circuit, as 

safety cannot be guaranteed.

 

Use the device in the hazardous “i” circuit only.

 

Devices which were used in a non-hazardous “i” circuit must 

be identified after they have been removed, denoting that 

their use is prohibited in the hazardous “i” circuit.

The  solenoid  coil  and  valve  body  form  a  closed  system  after 

installation. When used in explosion-risk areas, there is a risk of 

explosion if the system is opened in the operating state.

 

Do not remove or open the system during operation.

risk of explosion due to electrostatic discharge.

In the event of a sudden discharge from electrostatically charged 

devices  or  individuals,  there  is  a  risk  of  an  explosion  in  the 

explosion-risk area.

 

Take suitable measures to ensure that no electrostatic dis-

charges can build up in the explosion-risk area.

 

Do  not  use  the  device  in  areas  where  there  are  powerful 

charge-generating  processes,  mechanical  reaming  and  cut-

ting processes, the spraying of electrons (e.g. in the vicinity 

of electrostatic coating equipment) as well as pneumatically 

conveyed dust.

 

Clean the device surface by gently wiping it with a damp or 

antistatic cloth only.

english

PTB 01 ATEX 2175

Содержание PTB 01 ATEX 2175

Страница 1: ...ungsanleitung Manuel d utilisation PTB 01 ATEX 2175 Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21 Device with II 2G EX i approval Ger te mit II 2G EX i Zulassung Appareils avec m...

Страница 2: ...right to make technical changes without notice Technische nderungen vorbehalten Sous r serve de modifications techniques 2002 2018 B rkert Werke GmbH Co KG Operating Instructions 1810 15_EU ML_008045...

Страница 3: ...of the devices 8 5 1 Individual assembly block assembly 8 5 2 Operating temperature range 8 6 Technical data 8 6 1 Conformity 8 6 2 Standards 8 6 3 Operating conditions 8 7 Installation 12 7 1 Safety...

Страница 4: ...t followed 1 1 Definition of terms In these instructions the term device always refers to the solenoid coil AC21 1 2 Symbols Danger Warns of an immediate danger Failure to observe the warning may resu...

Страница 5: ...ation correct storage and installation as well as careful operation and maintenance Any other use is regarded as unauthorized B rkert is not liable for any result ing damage The user alone bears the r...

Страница 6: ...ion The device is a closed system and must not be modified in any way A device which has already been used in a non hazardous i circuit must no longer be used in the hazardous i circuit as safety cann...

Страница 7: ...power supply or pneumatic supply ensure that the process is restarted in a defined or controlled manner Don t use the device as a lever when screwing the valve into the line Failure to observe this o...

Страница 8: ...solenoid coil type AC21 conforms to the EU Directives as per the EU Declaration of Conformity if applicable 6 2 Standards EN 60079 0 2018 EN 60079 11 2012 The applied standards which are used to demo...

Страница 9: ...ee manual 6 Type serial number CE marking AC21 S N XXXXX CE0102 7 Order number date of manufacture xxxxxxxx month and year coded Tab 1 Description of the type label data 6 3 2 Coil dimensions Length m...

Страница 10: ...T6 Gb 6 3 4 Use in temperature class T6 Ignition protection type Ex ia Gas group II C Temper ature class Max permitted ambient temperature C Assembly Max per mitted power consumption Pi W T6 40 60 Blo...

Страница 11: ...The coils of type AC21 are available in two versions Version for use with 300 supply module 300 barrier High resistance version for use with other authorized supply modules Version Resis tance R20 Mi...

Страница 12: ...e power supply and secure to prevent reactivation The connection lines of the electromagnets must be per manently installed in such a way that they are adequately protected from mechanical damage Obse...

Страница 13: ...ed by electrostatic charge If there is a sudden discharge from electrostatically charged devices or persons there is a danger of explosion in the EX area Using suitable measures ensure that no electro...

Страница 14: ...tected equipment may be damaged during transport During transportation protect the device against wet and dirt in shock resistant packaging Avoid exceeding or dropping below the allowable storage temp...

Страница 15: ......

Страница 16: ...www burkert com...

Отзывы: