13

Assembly

Type 8228 ELEMENT

Transistor output

polarized

•  type

• 

NPN (/sink) or PNP(/source). 

Through wiring and through 

software setting

•  NPN output

• 

1...36 V DC, 700 mA max. (or 

500 mA max. if 2 transistor 

outputs are wired)

•  PNP output

• 

supply voltage, 700 mA max. 

(or 500 mA max. if 2 transistor 

outputs are wired)

•  protection

•  galvanically insulated, protected 

against overvoltages, polarity 

reversals and short-circuits

Current output

• 

specification

• 

4...20 mA, sink or source, 

through wiring and through 

software setting, 22 mA to 

indicate a fault (software 

setting)

•  type of connection

•  3-wire

•  maximum loop 

impedance

•  1100

 W

 at 36 V DC, 

 

610

 W

 at 24 V DC, 

 

100

 W

 at 12 V DC

•  Response time 

(10...90 %)

• 

150 ms (default value)

ASSEMBLY

7.1 

Safety instructions

WARNING

Risk of injury due to non-conforming assembly.

 

The device must only be assembled by qualified and skilled 

staff with the appropriate tools.

Risk of injury due to unintentional switch on of power supply 

or uncontrolled restart of the installation.

 

Avoid unintentional activation of the installation.

 

Guarantee a defined or controlled restart of the process 

subsequent to any intervention on the device.

7.2 

Mount the display module

NOTICE

 

The tightness of the device is not guaranteed when the 

housing lid is removed.

 

Prevent the projection of liquid inside the housing.

The device may be damaged if a metal component comes 

into contact with the electronics.

 

Prevent contact of the electronics with a metallic item.

english

Содержание ELEMENT 8228

Страница 1: ...Quickstart English Deutsch Fran ais Type 8228 Inductive conductivity meter Induktives Leitf higkeitsmessger t Conductim tre inductif...

Страница 2: ...reserve the right to make technical changes without notice Technische nderungen vorbehalten Sous r serve de modifications techniques B rkert SAS 2014 2022 Quickstart 2211 01_EU ML 00572159 ORIGINAL_E...

Страница 3: ...Safety instructions 13 7 2 Mount the display module 13 8 INSTALLATION 14 8 1 Safety instructions 14 8 2 Install a device variant with G2 nut in a pipe 15 8 3 Install a device variant with 2 clamp in...

Страница 4: ...A detailed description of the device can be found in the related Operating Instructions The Operating Instructions for the device can be found on the Internet at country burkert com 1 1 Definition of...

Страница 5: ...s could present risks to people nearby installations and the environment The Type 8228 ELEMENT conductivity meter is intended for the measurement of the conductivity of liquids Use the device in compl...

Страница 6: ...n in the installation stop the circulation of fluid cut off the pressure and drain the pipe Before any intervention in the installation make sure there is no pressure in the pipe Observe the dependenc...

Страница 7: ...instantly destroyed or disabled as soon as they are activated To minimise or even avoid any damage caused by an electrostatic discharge take all the precautions that are described in the EN 61340 5 1...

Страница 8: ...d quantity 3 Device version 4 Maximum power consumption 5 Maximum current available at a transistor output 6 Conductivity measuring range 7 Fluid temperature range 8 Pin assignment of an electrical co...

Страница 9: ...l 2000 m 6 2 Standards and directives The device complies with the relevant EU harmonisation leg islation In addition the device also complies with the require ments of the laws of the United Kingdom...

Страница 10: ...a ii PS 1000 bar 6 2 2 UL certification The devices with variable key PU01 or PU02 are UL certified devices and comply also with the following standards UL 61010 1 CAN CSA C22 2 n 61010 1 Identificat...

Страница 11: ...y 0 5 W cm 10 kW cm Temperature 40 150 C Concentration Conductivity to concentration conversion function Temperature compensation no compensation compensation according to a predefined curve NaCl NaOH...

Страница 12: ...riant with 2 clamp process connection PEEK EPDM Adapter for clamp stainless steel 316L 1 4404 6 5 Electrical data Operating voltage 12 36 V DC connection to main supply per manent through external saf...

Страница 13: ...DC 100 W at 12 V DC Response time 10 90 150 ms default value 7 ASSEMBLY 7 1 Safety instructions WARNING Risk of injury due to non conforming assembly The device must only be assembled by qualified and...

Страница 14: ...er for all the conductors and isolate it If the device is installed either in a wet environment or out doors all the electrical voltages must be of max 35 V DC All equipment connected to the device mu...

Страница 15: ...itting used Risk of injury due to unintentional switch on of power supply or uncontrolled restart of the installation Avoid unintentional activation of the installation Guarantee a defined or controll...

Страница 16: ...vity see chapter 9 7 Install the device in the fitting as shown in Fig 6 1 2 3 4 5 Make sure the seal mark 2 is on the conductivity sensor Make sure the material of the seal is compatible with the flu...

Страница 17: ...n example for the fitting mark 5 Mount the fitting on the pipe obeying the instructions of the operating instructions of the fitting used Fit the display module Refer to chapter 7 2 The display module...

Страница 18: ...e Once the device is wired set the HWMode parameter depending on the wiring carried out sink NPN or source PNP see chapter 9 6 8 4 1 Mating connector with article number 917116 To wire the product you...

Страница 19: ...uipment such as pumps or valves that is as close as possible to the device 12 36 V DC Power supply Metal pipe Fig 8 Equipotentiality skeleton diagram with pipes in metal 12 36 V DC Equipment such as v...

Страница 20: ...e available as an accessory article number 438680 Colour of the wire 1 brown 2 white 3 blue 4 black 5 grey or green yellow 12 36 V DC 1 2 3 4 Load brown grey or green yellow black white blue Power sup...

Страница 21: ...tor output PNP wiring and current output wiring in sourcing mode device variant with 1 connector parameter setting PNP source 8 4 4 Device variant with 2 connectors Male connector 1 2 3 4 Transistor o...

Страница 22: ...s accessories article number 438680 respec tively 559177 Colour of the wire 1 brown 2 white 3 blue 4 black 5 green yellow or grey 12 36 V DC 1 2 3 4 3 2 1 4 Load 1 1st 4 20 mA input at external instru...

Страница 23: ...source 9 ADJUSTMENT AND START UP The settings can only be done on a device with a display module Do not remove the display module while making the settings on the device 9 1 Safety instructions WARNI...

Страница 24: ...charge have read and fully understood the contents of this quickstart In particular observe the safety recommendations and intended use The device the installation must only be commissioned by suitabl...

Страница 25: ...select the highlighted function You want to Press browse in the dynamic functions bar MEAS BACK ABORT OK YES NO next function previous function confirm the highlighted dynamic function modify a numer...

Страница 26: ...or NO 9 4 Display module OPEN LOCK CondS 0 000 S cm TempC 23 8 C ERR Red LED shows an error not used Yellow LED shows that transistor 1 is switched Yellow LED shows that transistor 2 is switched Fig 1...

Страница 27: ...sage 9 5 Operating levels The device has 2 operating levels the Process level and the Configuration level When the device is energized or the display module is mounted on an energized device the displ...

Страница 28: ...the cleaned and dried conductivity sensor in contact with the ambient air Choose Yes Save or not the calibration result by choosing Yes or No 9 8 Enter the correction factor of the fitting used The c...

Страница 29: ...ends Fittings with internal or external thread connections or fittings with weld end connections Measurement chamber Welding sockets or fusion spigots PVDF PP PVC Brass Stainless steel Stainless stee...

Страница 30: ...culation of fluid cut off the pressure and drain the pipe Before any intervention in the installation make sure there is no pressure in the pipe Observe the dependency between the fluid temperature an...

Страница 31: ...he admissible storage temperature range Protect the electrical interfaces using protective plugs 12 STORAGE NOTICE Poor storage can damage the device Store the device in a dry place away from dust Sto...

Страница 32: ...32 Packaging Transport Type 8228 ELEMENT english...

Страница 33: ......

Страница 34: ...www burkert com...

Отзывы: