47
120 V AC - Design
11
120 V AC - DESIGN
11.1
Electrical connection options
Cable gland:
Connection left: Voltage, signals
Connection right: external initiator
Fig. 18: Connection concept 120 V AC
11.2
Electrical data
Central power supply:
110 ... 130 V AC, 50/60 Hz
Connections: Cable gland
1 x M16 x 1.5 cable gland/size22 - for power supply and signals
(only for transportation safety devices sealed with dummy plugs,
remove these before use!)
for cable diameter 5 ... 10 mm,
for wire cross-sections 0.5 ... 1.5 mm2 ,
including PE connection terminal
(tightening torque of the clamping screws max. 0.5 Nm)
1 x M16 x 1.5 cable gland/size19 - connection option for external
initiator (sealed with dummy plug, remove these before use)
Power consumption (standby current):
10 mA at 120 V AC
Solenoid valves:
Max. switching capacity:
1.7 VA (per solenoid valve)
Typ. continuous output:
1.4 VA (per solenoid valve)
Power consumption per solenoid valve: 12 mA at 120 V AC
Operating mode:
Long-term operation (100% ED)
Central display of the switching statuses:
13 mA with a power supply of 120 V AC per illuminated
display;
colour switching see chapter
Outputs/binary feedback signals:
S1out - S3out
Design:
Normally open contact, L switching,
short-circuit protection via automatically resetting fuse
Switchable output current: max. 50 mA per feedback signal
Output voltage - active:
≥ (operating voltage - 2 V)
Output voltage - inactive:
max. 1 V in unloaded state