13
6.4
Pneumatic installation
DANGER!
Risk of injury due to high pressure and any escaping media.
▶
Switch off the pressure before working on the device or system.
Vent or empty the lines.
Make the pressure supply as large-volume as possible.
Type 6524
3/R
X*
2/A
1/P
Type 6525
X*
5/R
4/A
1/P
2/B
3/S
Make the pressure
supply as large as
possible!
X* - pilot exhaust air
Fig. 10: Position of the connections, Type 6524 3/2-way valve and
Type 6525 5/2-way valve
Type 6524
(2 x 2/3-way valve)
12
14
— pole coil 12
actuated via bit “n+1”
— pole coil 14
actuated via bit “n”
Flange pattern "FM20"
+ pole
X*
5/R
4/A
1/P
2/B
3/S
Bit “n+1”
Bit “n”
Observe pin
assignment!
X* - pilot exhaust air
Hand lever
assignment
Fig. 11: Position of the connections, 2 x 3/2-way valve Type 6524
NOTE!
▶
Before the pneumatic installation, check the compatibility with
the valve island in question by means of the valve’s article
number (see the operating instructions of the corresponding
valve island).
English