Operating Instructions
Type 6524/6525
3/2-, 2x3/2- or 5/2-way solenoid valve for pneumatics
Страница 1: ...Operating Instructions Type 6524 6525 3 2 2x3 2 or 5 2 way solenoid valve for pneumatics ...
Страница 2: ... danger Fatal or serious injuries WARNING Potential danger Fatal or serious injuries CAUTION Danger Moderate or minor injuries NOTE Warns of damage Indicates instructions to avoid danger Indicates a procedure you need to carry out Inhaltsverzeichnis 1 Operating instructions 2 2 Intended use 3 3 Basic safety instructions 3 4 Structure and description 5 5 Technical data 6 6 Assembly installation 8 7...
Страница 3: ...vention and safety regula tions for electrical devices 2 INTENDED USE The device serves exclusively as a 3 2 2x3 2 or 5 2 way solenoid valve for the media that is permitted based on the data sheet for the corresponding type Do not use the device outdoors Use the device only in conjunction with third party devices and components that are recommended or approved by Bürkert Prerequisites for safe and...
Страница 4: ...cordance with the operating instructions Secure the device or system to prevent unintentional activation After an interruption in the power supply ensure that the process is restarted in a controlled manner Do not modify the device Do not mechanically load the device Only trained technicians may perform installation and maintenance work Only use suitable tools to perform installation and maintenan...
Страница 5: ... 5 1 Do not touch electronic components when the supply voltage is connected 4 STRUCTURE AND DESCRIPTION Type 6524 3 2 way valve Type 6524 2x3 2 way valve Type 6525 5 2 way valve The valves consist of a rocker pilot solenoid valve Type 6144 and a pneumatic seat valve Pilot valve and body are clamped together The principle allows the switching of high pressures together with low power consumption a...
Страница 6: ...or safety related shutdown 5 TECHNICAL DATA 5 1 Operating conditions WARNING Risk of injury due to malfunction if used outdoors Do not use the device outdoors Avoid heat sources that could lead to the permissible tempera ture range being exceeded NOTE Operate valve at temperatures below 0 C only with dry air Ambient temperature 10 55 C Medium temperature 10 50 C Medium Filtered compressed air max ...
Страница 7: ...e tolerance 10 Nominal power 1 W Nominal operating mode Continuous operation 100 duty cycle Electrical connection On valve Valve island Valve block Rectangular connector With grid 5 08 mm With integrated plug socket IP40 with rectangular connector 5 3 Type label example Germany 6524 C 2 5 10bar 24VBA0 8W W1XAW 00123456 1 4 3 2 Fig 2 Example of a type plate inscription Items Text Description 1 6524...
Страница 8: ...nstallation Only trained technicians may perform installation work Only carry out installations with suitable tools Secure the system against unintentional activation Following installation ensure a controlled restart WARNING Risk of injury due to uncontrolled movement of the actuators Back pressure in the exhaust air ducts can cause uncontrolled movements of the actuators Use large volume silence...
Страница 9: ... Flange seal Fig 3 Installation of the valve on the valve block tightening torques 6 2 Electrical installation pilot valve DANGER Risk of injury from electric shock Switch off the power supply before working on the device or system Secure against reactivation Observe the applicable accident prevention and safety regula tions for electrical devices NOTE Observe voltage In case of alternating voltag...
Страница 10: ...electrical power and current type Voltage tolerance 10 At 100 duty cycle and maximum ambient temperature the coil heats up in single assembly to approx 105 C in block assembly to approx 120 C 6 2 1 Pin assignment 3 2 and 5 2 way valve 2x3 2 way valve JB17 JB18 14 12 JB20 14 12 JB21 14 12 JF79 Fig 5 Pin assignment 3 2 5 2 and 2x3 2 way valves English ...
Страница 11: ...riant MA06 with electrical connection rotated by 180 6 2 2 Pin assignment variant PF34 for safety related switch off Single valve 12 3 2 way valve WWC Type 6524 5 2 way Valve WWH Type 6525 Wire colours BK black RD red 24 V 12 12 BK RD JB17 BK RD Fig 7 Pin assignment variant PF34 3 2 and 5 2 way valve English ...
Страница 12: ...valve manually turn the manual override 90 in the direction of the arrow on figure 1 This puts the valve into the switched state The valve remains fixed in the switched state until the manual override is turned back to its original position For the double valve 2x3 2 way the upper manual override switches output 2 A while the lower manual override switches output 4 B 1 1 1 Fig 9 Manual override of...
Страница 13: ...tion of the connections Type 6524 3 2 way valve and Type 6525 5 2 way valve Type 6524 2 x 2 3 way valve 12 14 pole coil 12 actuated via bit n 1 pole coil 14 actuated via bit n Flange pattern FM20 pole X 5 R 4 A 1 P 2 B 3 S Bit n 1 Bit n Observe pin assignment X pilot exhaust air Hand lever assignment Fig 11 Position of the connections 2x3 2 way valve Type 6524 NOTE Before the pneumatic installatio...
Страница 14: ...80 7 START UP WARNING Risk of injury due to improper operation Prior to start up it must be ensured that the operating personnel are familiar with and fully understand the contents of the operat ing instructions Only authorised technicians may start up the device or system Check correct connection of pressure and tension For electrical operation unlock the manual override 0 position Create print f...
Страница 15: ...the exhaust air ducts to blow out the impurities Install a new pilot or main valve 8 MAINTENANCE TROUBLESHOOTING WARNING Risk of injury due to improper maintenance work Only trained technicians may perform maintenance work Secure the system against unintentional activation Ensure a controlled restart after maintenance is completed The valves are maintenance free when operated according to the inst...
Страница 16: ...rm disassembly work Loosen the two fastening screws Carefully pull the valve off the valve block 10 TRANSPORTATION STORAGE DISPOSAL NOTE Damage in transit due to inadequately protected devices Protect the device against moisture and dirt in shock resistant packaging during transportation Observe permitted storage temperature Incorrect storage may damage the device Store the device in a dry and dus...
Страница 17: ...m Internet www buerkert de Manuels d utilisation et fiches techniques sur Internet www burkert fr Bürkert Werke GmbH Co KG 2001 2022 Operating Instructions 2208 12_EUml_00803840 Original DE Bürkert Fluid Control Systems Sales Center Christian Bürkert Str 13 17 D 74653 Ingelfingen Tel 49 0 7940 10 91 111 Fax 49 0 7940 10 91 448 E mail info burkert com ...