13
Technical data
0 20 40 60 80 100 120 140 160 180 200 220
50
60
110
100
90
80
70
Medium temperature [
°C
]
Ambient t
emper
atur
e [°
C
]
Image6:DeratingElementANTG 50,70,90,130
7.4.2
Pressure ranges
Actuator size [mm]
Maximum pilot pressure
5)
ø 50, ø 70, ø 90
10 bar
ø 130
7 bar
Tab.5: Pressureranges
Medium pressure and pilot pressure for control function A, flow
direction below seat (standard):
DN
Maximum medium pressure
[bar]
Minimum pilot pressure
[bar]
Actuator size ø [mm]
Actuator size ø [mm]
50
70
90
130
50
70
90
130
15
25
25
-
-
5.2
4.8
-
-
20
16
25
5.2
4.8
25
9.0
16
25
5.2
4.8
5.0
32
-
8.5
25
-
4.8
5.0
40
6.0
16
25
4.8
5.0
5.0
50
4.0
10
25
4.8
5.0
5.0
65
-
5.0
16(15
6)
)
-
5.0
5.6
80
-
10
-
-
100
6.0
Tab.6: MediumandpilotpressureCFA,standard
6)
AccordingtoPressureEquipmentDirectiveforcompressiblefluidsof
Group 1(dangerousgasesandvapoursaccordingtoArt.3,No. 1.3,
letter a,firstdash)
Type 2101