10
NOTE!
Important information:
• Avoid emitting pulses simultaneously to both coil windings.
• Do not switch any other consumers (relays, etc.) at the same time
as the terminals.
• The coil connection, to which voltage is not applied, must be galvani-
cally isolated (open).
• If two or more valves are switched in parallel, ensure that this
requirement is met by using 2-pole or multi-pole switches.
6
MAINTENANCE, TROUBLESHOOTING
6.1 Safety instructions
WARNING!
Risk of injury from improper maintenance!
▶
Maintenance may be carried out by authorized technicians only and
with the appropriate tools!
Risk of injury from unintentional activation of the system and an
uncontrolled restart!
▶
Secure system from unintentional activation.
▶
Following maintenance, ensure a controlled restart.
6.2 Malfunctions
Type 0340: Shipment may have caused the position to occupy a
middle position.
Procedure:
→
Apply pressure to connection P and briefly seal connection A/B,
→
Using your finger, press piston through connection R into the end
position.
english